Alarm reset
3.6
Shutdown warning
Description
A shutdown warning will appear in the event of:
• A too high temperature at the outlet of the compressor element.
Compressor element outlet temperature
• If the outlet temperature of the compressor element exceeds the shutdown warning level
(factory set at 110˚C/ 230˚F), warning LED (5) is on.
• Press Scroll up or down buttons (4-8). The screen shows the temperature at the compressor
element outlet.