background image

12

Geberit Tessera

TM

Toilet System

Installation & Maintenance Instructions

CHICAGO FAUCETS WARRANTY / GEBERIT BRAND PRODUCT

Geberit Tessera

TM

Toilet System

Chicago Faucets will either replace or repair the defective equipment or refund the purchase price, at its option, if an inspection by Chicago Faucets
or its authorized representative discloses any manufacturing defects in material or workmanship during this period
Chicago Faucets will not be liable for any labor or other expenses not specifically stated above, and disclaims any responsibility for incidental or 
consequential damages. Warranties implied by law, including that of merchantability, are expressly limited to the period of this warranty, This limita-
tion and exclusion does not apply in those states that do not allow limitations on the duration of implied warranties. Or the exclusion may not apply 
to you. This warranty gives you specific legal rights and you may have other rights, which vary from state to state.

PROBLEM

POSSIBLE CAUSE

POSSIBLE SOLUTION

WATER CONTINUES TO RUN
INTO THE BOWL AFTER
FLUSH CYCLE IS COMPLETE

Flush valve is not seated properly.

The water level is to high in the tank. Water over-
flows into overflow tube.

Water is spraying from top of fill valve from refill
tube.

Actuator rod is improperly installed.

Water in tank is less than 1.6 GAL - 6.0 LTR.

Bowl trap way or drain line is clogged.

Hex nuts are not tighten appropriately.

Improper wall surface used to mount bowl.
Gypsum-green board, cement board, tile backer
board or ceramic tile surface are recommended
materials for mounting.

- Excess length of air tube used in installa-

tion; tube is too long to allow sufficient 
air to reach from push button to lifter 
assembly.

- Air tube is kinked or pinched.

- Air tube connections loose.

- Lifter assembly is misaligned

- Lifter assembly does not sufficiently 

move when acturator is pushed.

Remove actuator or access panel to reach flush
valve. Pull out flush valve check seat gasket for
proper attachment. Reinstall valve test for function.

Remove actuator or access panel. Turn fill valve
adjustment rod counter clockwise to lower water
level in tank.

Remove actuator or access panel.
Replace fill valve.

Remove actuator plate reset actuator rod following
directions on page 9 position 8.

Remove actuator or access panel.
Turn fill valve adjustment rod clockwise to increase
water level in tank.

Plunge toilet bowl, if no result, use snake as nee-
ded.

Remove bolt caps, tighten hex nuts that bowl is
firmly attached to wall.

Dismount bowl, rebuild wall with material as
recommended.
PREVENT ANY SPACE BETWEEN CARRIER
FRONT AND WALL MATERIAL

Remove tank access cover, turn off water supply 
stop and flush tank.
Check for and adjust excess tubing.

-  Remove kinks in air tubing

-  Reset air tube connections

- Remove lifter assembly from flush valve and 

replace as whole.

WASTE IS NOT REMOVED
FROM BOWL

BOWL IS BECOMING LOOSE

UNCOMPLETED FLUSH
CYCLE

REMOTE ACTUATOR
UNCOMPLETED FLUSH
CYCLE

Summary of Contents for Geberit Tessera

Page 1: ...is manual is subject to change without notice Notice to Installers Please leave this manual with the facility manager after completing the TesseraTM Toilet System Installation This document contains information necessary for routine maintenance and servicing TABLE OF CONTENTS Product Overview 2 Features 2 In Compliance with 2 Available Options 2 How to Order 2 Technical Support 2 Product Specifica...

Page 2: ... condensation IN COMPLIANCE WITH ASME 112 19 2 ASME 112 6 2 CSA B125 ASSE 1002 AVAILABLE OPTIONS White wall hung bowl 111 870 DY 1 Bone wall hung bowl 111 870 AA 1 Biscuit wall hung bowl 111 870 FF 1 White closed front seat 113 050 DY 1 Bone closed front seat 113 050 AA 1 Biscuit closed front seat 113 050 FF 1 Tile cushion pad 156 055 00 1 Remote Flush Actuator 115 941 XX 1 Access panel drywall 11...

Page 3: ...oard Ceramic tile surface Total thickness not to exceed 2 R H 15 to 19 380 482 22 558 61 2 165 95 8 245 1 2 UNC 12 305 SAFETY INFORMATION Read this entire instruction sheet to ensure proper installation Compliance and conformity to local building codes and ordinances is the responsibility of the installer Compliance and conformity to local fire codes and ordinances is the responsibility of the ins...

Page 4: ...plate and floor to clear passage for discharge fitting at required location 3 Place the carrier assembly in the prepared opening 4 THE CARRIER FRAME MUST BE FLUSH WITH THE FRONT OF THE SUPPORTING STUDS to provide maxi mum support for the wall surface material applied later 5 Mark the 6 anchor hole locations on the sole plate and the 6 bolt hole location 3 each side on the studs 6 Remove the carrie...

Page 5: ...alve in shut off position du not connect fill valve supply hose until the installation is completet 4 1 2 3 5 6 1 Attach and secure mud guard onto tank access window 2 Install tank access cover plate snap in 3 Install blue mud guard cover snap on 1 Install two 2 1 2 x 6 threaded rods A supplied into the tank carrier frame extending approximately 4 from frame 2 Install protective clear plastic slee...

Page 6: ...ce a straight edge flush against the wall and across the fill pipe and mark dimension A Repeat for discharge adaper 5 Remove inlet and discharge adapters from tank carrier assembly 1 Install the inlet and discharge adapters with gaskets fully into the bowl 2 Measure and mark dimension B on both pipes 3 Remove pipes and gaskets from bowl 1 Add dimensions A and B then subtract 1 8 to get dimension C...

Page 7: ...vided Do not use plumbers putty or Silicone sealant 2 Install both adapters into appropriate wall side hub 1 Place the bowl onto the fixture rods 2 Install cap retainers 1 washers 2 and nuts 3 Secure bowl with nuts handtight only Note Cap retainers 1 should be installed with the larger end facing up 3 Level the bowl then tighten nuts DO NOT OVERTHIGTEN NUTS 4 Snap caps over cap retainers 4 3 1 up ...

Page 8: ...Tank water level WL must be 3 4 below over flow level OFL 2 1 Remove mud guard cover 2 Trim off excess material to be flush with wall 3 Discard cover and excess material Lift out cover plate 4 5 1 Install two 2 threaded lock pins part of actuator assembly 2 Adjust lock pin length to be flush with finished wall turn to lock in place 1 Reset cover plate in tank opening interlock with two 2 bracket s...

Page 9: ...nstall rod and tum clockwise to lock it into the bushing 9 7 1 Place actuator frame onto front of box with spring at the bottom facing outward 2 Secure frame onto lock pins with two 2 self tapping screws provided A C B push 1 To complete the installation attach the actuator plate on to spring at lower side push up and snap the upper edge onto frame 2 Secure actuator plate to frame test for functio...

Page 10: ...s clogged Hex nuts are not tighten appropriately Improper wall surface used to mount bowl Gypsum green board cement board tile backer board or ceramic tile surface are recommended materials for mounting Excess length of air tube used in installa tion tube is too long to allow sufficient air to reach from push button to lifter assembly Air tube is kinked or pinched Air tube connections loose Lifter...