![Chicago Faucets Geberit Tessera Installation Instructions Manual Download Page 5](http://html.mh-extra.com/html/chicago-faucets/geberit-tessera/geberit-tessera_installation-instructions-manual_2598853005.webp)
5
Geberit Tessera
TM
Toilet System
Installation & Maintenance Instructions
1. Water supply specification,
1
/
2
” copper - supply pressure
25 - 90 PSI.
2. Extend drop ear elbow supply side with 1/2” x 6” copper
nipple, secure elbow to cross brace (2” x 4” x 19
3
/
4
”) and
install in back of the tank reset section.
3. Remove tank door, install
1
/
2
” NPT shut off valve through
tank opening. Keep valve in shut off position, du not
connect fill valve supply hose until the installation is
completet.
4
1.
2.
3.
5
6
1. Attach and secure mud guard onto tank access window.
2. Install tank access cover plate (snap in).
3. Install blue mud guard cover (snap on).
1. Install two (2)
1
/
2
” x 6” threaded rods A (supplied) into
the tank & carrier frame extending approximately 4” from
frame.
2. Install protective clear plastic sleeves (provided) on to
threaded fixture rods.
3. Install protective pipe plugs B (provided) in the opening
of the flush pipe and discharge fitting.
TANK & CARRIER INSTALLATION
A
B