8.

IMPORTANT:  When the YELLOW Light illuminates on the LED Display (3),
immediately turn off the Power System and recharge the Battery.  Operating the
Power System with the YELLOW Light illuminated may result in damage to the
Battery.  (See Figure B.)

9.

NOTE:  The Lights on the LED Display
(3) indicate the following:
(See Figure B.)

FIGURE B

To Power 12 VDC Tools And Appliances:

1.

The Power System may be used to power various 12 VDC small power tools and
appliances (i.e., 12 VDC drills, screwdrivers, cellphones, televisions).

2.

To power a 12 VDC power tool or appliance, insert the 12 VDC Cigarette Lighter
Plug (12) into a 12 VDC Output (4).  Insert the other end of the 12 VDC Cigarette
Lighter Plug into the power input of the tool or appliance.  Then, turn the Power
Switch (2) to its “ON” position.  (See Figure A.)

3.

When finished using the 12 VDC tool or appliance, unplug the 12 VDC Cigarette
Lighter Plug (12) from the 12 VDC Output (4).  Unplug the other end of the
12 VDC Cigarette Lighter Plug from the power input of the tool or appliance.
Then, turn the Power Switch (2) to its “OFF” position.  (See Figure A.)

4.

As soon as possible, recharge the Power System.

To Power 3 VDC, 6 VDC, And 9 VDC Tools And Appliances:

1.

Determine what voltage your tool or appliance operates on.

2.

Use a dual modular connection cord (not included) to attach the tool or appliance
to either the 3 VDC Output (5), 6 VDC Output (6), or 9 VDC Output (7).  NOTE: a
dual modular connection cord may be purchased at your local electronics
supplier, if one is not included with the tool or appliance.  (See Figure A.)

3.

CAUTION!  Make sure to use the correct Power System Output (5, 6, 7) to
power those devices whose voltage match those of the Output.

To Operate The Emergency Light:

The Power Switch (2) controls the Emergency Light (10).  Turn the Power Switch
to its “ON” position to turn on the Emergency Light.  Turn the Power Switch to its
“OFF” position to turn off the Emergency Light.  (See Figure A.)

GREEN - FULL CHARGE (ON)

RED - CHARGING

YELLOW - LOW BATTERY

GREEN - CHARGING (FULL)

Summary of Contents for 92476

Page 1: ...T SERIOUS INJURY READ AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS BEFORE USE Copyright 2004 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools For technical questions or replacement parts please call 1 800 444 3353 ...

Page 2: ...erious injury SAVE THESE INSTRUCTIONS UNPACKING When unpacking check to make sure all the parts shown on the Product Features Listing on page 7 are included If any parts are missing or broken please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible WARNING Item Description Electrical Requirements Voltage Input 120VAC 60Hz Rechargeable Initial Charge Time...

Page 3: ...gging a power tool or appliance into its Output Sockets Plugging in with the Power Switch ON invites accidents 4 Do not overreach Keep proper footing and balance at all times Proper footing and balance enables better control of the Power System in unexpected situations 5 Use safety equipment Always wear ANSI approved safety impact eye goggles when using the Power System TOOL USE AND CARE 2 Do not ...

Page 4: ...ced before using Many accidents are caused by poorly maintained equipment 7 Use only accessories that are recommended by the manufacturer for your model Accessories that may be suitable for one Power System may become hazardous when used on another Power System SERVICE 1 Equipment service must be performed only by qualified repair personnel Service or maintenance performed by unqualified personnel...

Page 5: ...er Switch is left in the ON position Make sure the Power Switch is in its OFF position before leaving 8 Make sure to read and understand all instructions and safety precautions as outlined in the manufacturer s manual for the products for which the Power System will power 9 Never attempt to use the Power System to jump start a vehicle 10 Make sure to turn off the Power Switch of the product to be ...

Page 6: ...ction When working on or around lead acid batteries always wear ANSI approved safety impact eye goggles 18 Use the Power System in a well ventilated area If necessary wear an ANSI approved breathing respirator to avoid hydrogen gas fumes 19 Proper Battery Care Battery leakage may occur under extreme usage or temperature conditions If Battery fluid comes in contact with skin wash with soap and wate...

Page 7: ...12 13 14 15 FIGURE A 1 POWER INPUT 2 POWER SWITCH 3 LED PANEL 4 12 VDC OUTPUTS 5 3 VDC OUTPUT 6 6 VDC OUTPUT 7 9 VDC OUTPUT 8 3 VDC 6 VDC 9 VDC OUTPUT FUSE 9 CARRYING STRAP 10 EMERGENCY LIGHT 11 12 VDC OUTPUT FUSE 12 12 VDC CIGARETTE LIGHTER PLUG 13 12 VDC CIGARETTE LIGHTER PLUG FUSE 14 CAP 15 120 VAC ADAPTER ...

Page 8: ... illuminate Then turn the Power Switch to its OFF position 5 Once fully charged disconnect the 120 VAC Adapter 15 from its electrical outlet Then disconnect the Charging Plug of the Adapter from the Power Input 1 on the right side of the Power System NOTE The temperature of the Battery and or 120 VAC Adapter may increase slightly during use and shortly after use which is normal The Battery may not...

Page 9: ...C Cigarette Lighter Plug 12 from the 12 VDC Output 4 Unplug the other end of the 12 VDC Cigarette Lighter Plug from the power input of the tool or appliance Then turn the Power Switch 2 to its OFF position See Figure A 4 As soon as possible recharge the Power System To Power 3 VDC 6 VDC And 9 VDC Tools And Appliances 1 Determine what voltage your tool or appliance operates on 2 Use a dual modular ...

Page 10: ...ut of its receptacle and insert a new Fuse in its receptacle See Figure A 5 To replace the 12 VDC Cigarette Lighter Plug Fuse 13 The type of Fuse is 5 AMP Glass To replace unscrew and remove the Cap 14 Then remove the old Fuse Install a new Fuse and replace the Cap See Figure A 8 CAUTION All maintenance service or repairs not listed in this manual are only to be attempted by a qualified service te...