Electric Induction hobs Chef’s EH-MIX544 / 545
- 21 -
general [ON/OFF] key and the [KEYLOCK].
When the cook top is off, the key lock function locks all the keys, including the general
[ON/OFF] key.
The key-lock is always activated at the start up of the control.
Fig. 17: Key Lock
13. Relay Ton / Toff for radiant heaters
The relay Ton/ Toff (Duty Cycle) , are shown in the
Table.2
depending on the power
level.
Power level
Ton(sec)
Toff(sec)
Power %
1
1.3
42.7
3.1
2
2.8
41.2
6.3
3
6.2
37.8
14.1
4
8.2
35.8
18.6
5
11
33
25.0
6
13.8
30.2
31.3
7
19.9
24.1
45.3
8
28.2
15.8
64.1
9
44 “
-----
100
Table 2: Relays Ton/Toff vs. power level
14. Residual heat time calculation for radiant heaters
While a temperature on the cook top glass surface is above 65ºC, this
condition will be shown in the associated display, by means of a “H”.
If the cook top is switched off, the residual heat is shown by a static “H” in the
display.