42
LAVA STONE GRILL - EASY 700
Instructions for qualified fitters
UM300010
- 10/2019
©
Copyright 2019
6
6.7.2 Checking the supply pressure
The connection pressure is measured when the appliance is running using a pressure gauge as follows:
- Remove the front panel after removing all the knobs;
- Remove the screw and sealing ring from the manometric pressure socket;
- Connect the pressure gauge and check the pressure. If the pressure falls within the nominal values
indicated (see par.
Characteristics and requirements of the gas supply network
) the appliance
can be used; otherwise contact the gas supply company;
-
After checking the pressure, remove the pressure gauge and refit the screw and corresponding sealing
ring. Using red paint, seal the pressure control screw, then refit the front panel and knobs.
IMPORTANT
The Manufacturer shall not be held responsible for any damage to people or objects caused by
installation errors.
Fig. 20 Manometric pressure socket