43
LAVA STONE GRILL - EASY 700
Instructions for qualified fitters
UM300010
- 10/2019
©
Copyright 2019
6
6.7.3 Checking the extraction of combustion products
Carry out the following checks:
- check that the exhaust gases come out correctly from the special ducts;
- check that nothing obstructs air intake or heat extraction openings;
- check that any combustion product extraction system (extraction hoods or other) permits extraction of at
least 1 cubic meter of fumes per kW of power absorbed by the connected appliances.
6.7.4 Checking ventilation of the installation premises
Carry out the following checks:
-
check that the area where the appliance is installed is well-ventilated during operation, with air flow for
gas combustion as well as for air exchange (ventilation);
- air intake openings must be placed in the lower part of the external walls, preferably opposite the wall
where the extraction of combustion gases is situated;
- air intake openings must be built in such a way that they cannot be obstructed.
6.7.5 Instructions for users
After testing, if necessary, train users so that they acquire all the necessary skills to start-up the appliance
in safe conditions, as provided for by applicable regulations.
IMPORTANT