39
LAVA STONE GRILL - EASY 700
Instructions for qualified fitters
UM300010
- 10/2019
©
Copyright 2019
6
In compliance with applicable legislation on installation, the appliance can be defined as
Type A1
:
an appliance not intended for connection to a chimney/flue or to a device for the extraction of combustion
products to the outside of the premises where the appliance is installed. The extraction of comburent air
and combustion products is carried out in the installation premises.
To guarantee the complete extraction of steam produced during cooking and gases produced during
the combustion process, the appliance must be installed in well-ventilated premises (possibly under a
mechanical extraction hood), in compliance with applicable regulations.
If a mechanical extraction hood is installed, it is necessary to follow the regulations for the installation
below.:
- Gas supply to the appliance must be interrupted if the power of the forced extraction system falls under
the established safety value; the gas supply must only be restored manually.
-
The final part of the appliance extraction duct must be about
1,8 m
from the appliance support surface;
the outlet of the combustion product extraction duct must be placed within the basic perimeter of the
hood (see figure below).
- The power of the mechanical extraction system must not be lower than required.
Fig. 18 Fume extraction
1,8 m
Fig. 19 Fume extraction through extraction hood