Important
Upon completion of installation,
always check:
-
That all the joints are completely
sealed by using a soapy solution,
never a flame;
-
That the gas pressure has been
regulated to 1,00 kPa for Natural
Gas and 2,60 kPa for Universal-
LPG. The pressure test point is
located on the regulator for
Natural Gas models or at the top
left hand rear of the cooker for U-
LPG models.
-
That the manual ignition system
is operating satisfactory on all
burners, both individually and in
combination;
-
That the burners correctly, are
stable, without yellow tipping or
excessive noise on high and low
flame.
Then demonstrate to the customer
the appliance operation and leave
these instructions.
Adaptation to different type of gas
Your cooker is designed to work with
natural gas, and is convertible for use
with propane or butane.
The U-LPG conversion kit is supplied
in the instruction manual packaging.
After completion of any repairs,
adjustments or conversion the
statutory safety tests, must be
carried out.
Stick the label corresponding
to the type of gas used.