25. MENU 09
– STOVE STATUS
This menu gives advanced information on the stove status and has to by use by dealer’s authorized personnel only.
.Here are the matches of the state indicated on the display:
STATUS 0 = STOVE OFF
STATUS 1 = STOVE ON
STATUS 2 = STOVE WAS ON HOLD or HOLD FIRE BURNOUT
STATUS 3 = FIRE PRESENT
STATUS 4 = STOVE WORK
STATUS 5 = BURNER CLEANING
STATUS 6 = FINAL CLEANING
STATUS 7 = STOVE WAS WAITING FOR COOLING FROM STAND-BY
STATUS 8 = ALARM WAS ACTIVE IN STOVE
STATUS 9 = STOVE WAS IN MEMORY ALARM
26. MENU 10
– SERVICE SETTINGS
To be entered by trained service center technicians only (password required).
27. MENU 11
– DEALER SETTINGS
To be entered by trained dealer technicians only (password required).
28. MENU 12
– FAN ENABLE
GIGIO and SYLVESTER: Menu not enabled.
Serbis: Menu RESTRICTED EXCLUSIVELY FROM AUTHORIZED SERVICE. Do not change the factory setting ON.
1)
Select menu
12 (button 7 and
then button 2)
2)
Press button
7 to enter the
menu
3)
The OFF or
ON setting will
be displayed
4)
Press button
2 to select the
setting.
5)
Press button
7 to confirm
6)
Press button
3 to back to the
menu
29. STOVE STARTING
After having correctly installed the appareil do as follows for starting it:
- fill the stove’s pellet tank up
- run the first pellet loading program (MENU 08) at first starting only.
- follow this procedure:
1)
Press red
button 3 for 3
seconds
2)
START will
be displayed.
3)
After some
10” “LIGHTER-
WAIT“ will be
displayed.
4)
After some 1’
“LOAD PELLET”
will be
displayed.
5)
After some 3’
“FIRE WAIT” will
be displayed.
6)
After some 4’
“FLAME LIGHT”
will be displayed
MENU 12
ENABLE
BLOWER
ON
MENU 07
ENABLE
BLOWER
14 :00
28.5
°
P-1
START
14 :00
28.5
°
P-1
LIGHTE
R
WAIT
14 :01
28.5
°
P-1
load
PELLET
14 :04
28.5
°
P-1
FIRE
WAIT
14 :08
28.5
°
P-1
FLAME
LIGHT
14 :10
28.5
°
P-
1
WORK