22
ENG
GIGIO - SILVESTRO - SERBIS
(Rev. 01/07/2012)
10. CONNECTING TO THE EXISTING SMOKESTACK
. Piping with classification “O” and minimum distance in millimeters xx is allowed provided that in case of soot fire all
connecting piping will be fully replaced in order to restore the original conditions. Please make sure only 3 directions
changing of maximum 90° and a 4 meters horizontal segment are allowed (check following examples).
GIGIO
– SILVESTRO:
Example with 2 bends 90° Example with 3 bends 90° (maximum allowed)
SERBIS:
Example with 2 bends 90° Example with 3 bends 90° (maximum allowed)
The appliance can be connected to an existing smokestack only after carefully checking it. In case the smokestack
doesn’t show the approved tag, a registered chimneysweeper has to certify it.
When connecting to non isolated smokestacks, draught problems can occur. It is however forbidden connecting the
stove to smokestack with a diameter bigger than 200 millimeters; if the case slot-in a 120 – 150 millimeter pipe up to
Max
4 m
(mi
n. 3
%)
ø 100 mm
min.
1
2
3
1
2
ma
x 4
m
inc
lina
tio
n
> 3
%
Fig. 10
Fig. 11
Fig. 12
INSULATING
CONNECTOR T
CONNECTOR T
CLEANING
DIRECTION
CLEANING
DIRECTION
CLEANING DIRECTION
Max
4 m
(mi
n. 3
%)
ø 150 mm min
1
2
3
1
2
ma
x 4
m
inc
lina
tio
n
> 3
%
Fig. 10
Fig. 11
Fig. 12
Ø 150 min
INSULATING
CONNECTOR T
CONNECTOR T
CLEANING
DIRECTION
CLEANING
DIRECTION
CLEANING DIRECTION