ANALOGUE OUTPUT
Transformation ratio Vout : 1mV/A or 10mV/A
A mini-switch, located inside the clamp, selects this ratio ; the clamp is originally confi-
gured with the ratio 1mV/A.
Measurement extent
- Ratio 1mV/A: 0.05A to 700A RMS or 1000A PEAK
- Ratio 10mV/A: 0.05A to 60A RMS
Typical accuracy : 3%
Frequency range : Idem currents
Output impedance : 4k
Ω
Protection : The Vout output is protected from the accidental application of a voltage to its
terminals, but in this case the metrological specifications are no longer guaranteed.
GENERAL SPECIFICATIONS
POWER SUPPLY
- 1 battery 9V (type 6LF22 or NEDA 1604)
- Average service life 50h
NB : . service life limited to 8 hours on RECORD - THD and DF.
. also see the chapters Checking the battery and Replacing the battery.
CLIMATIC CONDITIONS
Use
- Temperature from -10°C to +55°C
- Relative humidity from 0 to 80% RH up to 30°C
- Altitude up to 2000m
I
Reference range
II
Working range
III
Storage range
-50°
-40°
-30°
-20°
-10°
0°
10°
20°
30°
40°
60°
50°
70°
80°
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
III
II
I
Humidity in % RH
temperature in °C
45
46
www.motralec.com / [email protected] / 01.39.97.65.10