Obsession™ LED 2.0 User Manual (Rev. 03)
Page 7 of 20
3.
S
ETUP
AC Power
This product has an auto-ranging power supply and can work with an input voltage
range of 100~240 VAC, 50/60 Hz.
To determine the power requirements for this product (circuit breaker, power outlet, and
wiring), use the current value listed on the label affixed to the product’s back panel, or
refer to the product’s specifications chart. The listed current rating indicates the
product’s average current draw under normal conditions.
Always connect this product to a protected circuit (circuit breaker or fuse),
making sure it has an appropriate electrical ground to avoid the risk of
electrocution or fire.
Never connect this product to a rheostat (variable resistor) or dimmer circuit, even
if the rheostat or dimmer channel serves only as a 0 to 100% switch.
Fuse
Replacement
Follow the instructions below to change the fuse, if necessary.
Disconnect this product from the power outlet before replacing the fuse.
1. Wedge the tip of a flat head screwdriver into the slot of the fuse holder and pry out of
the housing.
2. Remove the blown fuse from the holder and replace with a fuse of the exact same
type and rating.
3. Insert the fuse holder back into place and reconnect power.
The product does not ship with a spare fuse; however, the safety cap has room
for a spare.
Always replace a blown fuse of the same type and rating.
Installed
fuse
(held
by
plastic
clip)
Spare
fuse
holder
(inside
safety
cap)
Safety
cap