background image

 

CH-160A User Manual 

2005-12-08/17:20 

A

PPENDIX

 

General Maintenance 

To maintain optimum performance and minimize wear fixtures should be cleaned frequently.  Usage 

and environment are contributing factors in determining frequency. As a general rule, fixtures should 

be cleaned at least twice a month. Dust build up reduces light output performance and can cause 

overheating. This can lead to reduced lamp life and increased mechanical wear. Be sure to power off 

fixture before conducting maintenance. 

Unplug fixture from power. Use a vacuum or air compressor and a soft brush to remove dust 

collected on external vents and internal components.  Clean all glass when the fixture is cold with a 

mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. Apply 

solution to the cloth or tissue and drag dirt and grime to the outside of the lens. Gently polish optical 

surfaces until they are free of haze and lint. Do not to touch the lamp glass when cleaning fixture. Oil 

and dirt can cause damage and premature aging of the lamp. In the event that the lamp is touched or 

becomes dirty, clean the lamps with an alcohol wipe.  

The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to 

optimize light output. Cleaning frequency depends on the environment in which the fixture operates: 

damp, smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit

optics. Clean with soft cloth using normal glass cleaning fluid. - Always dry the parts carefully. - Clean 

the external optics at least every 20 days. Clean the internal optics at least every 30/60 days. 

Returns Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 

Package must be clearly labeled with a Return Merchandise Authorization Number (RA #). Products 

returned without an RA # will be refused. Call CHAUVET and request RA # prior to shipping the 

fixture. Be prepared to provide the model number, serial number and a brief description of the cause 

for the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate 

packaging is the customer

s responsibility. CHAUVET reserves the right to use its own discretion to 

repair or replace product(s). As a suggestion, proper UPS packing or double-boxing is always a safe 

method to use. 

Claims 

Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 

reported to the carrier upon receipt of merchandise. It is the customer's responsibility to notify and 

submit claims with the shipper in the event that a fixture is damaged due to shipping.  Any other claim 

for items such as missing component/part, damage not related to shipping, and concealed damage, 

must be made within seven (7) days of receiving merchandise.  

Summary of Contents for Duo Moons CH-160A

Page 1: ...Chauvet 3000 N 29 th Ct Hollywood FL 33020 U S A 800 762 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com 2005 12 08 17 20 CH 160A Duo Moons USER MANUAL ...

Page 2: ... INSTRUCTIONS 3 AC POWER 3 SAFETY INSTRUCTIONS 3 INTRODUCTION 4 FEATURES 4 PRODUCT OVERVIEW 4 SETUP 5 LAMP 5 Lamp installation 5 MOUNTING 5 Orientation 5 Rigging 5 OPERATING INSTRUCTIONS 6 APPENDIX 7 GENERAL MAINTENANCE 7 RETURNS PROCEDURE 7 CLAIMS 7 GENERAL TROUBLESHOOTING 8 TECHNICAL SPECIFICATIONS 9 TECHNICAL SUPPORT 9 ...

Page 3: ...er user be sure that they also receive this instruction booklet Always make sure that you are connecting to the proper voltage and that the line voltage you are connecting to is not higher than that stated on decal or rear panel of the fixture This product is intended for indoor use only To prevent risk of fire or shock do not expose fixture to rain or moisture Make sure there are no flammable mat...

Page 4: ... Independent flashing rotating static modes Additional optional dishes sold separately Product Overview Hanging Bracket Microphone NOTICE This is not a power switch Mode Switch ON Sound Activated Dishes will rotate back and forth to the sound OFF Auto Programs Dishes will rotate back and forth automatically and not by sound Fuse holder Lamp cover plate Plate removed and lamps exposed ...

Page 5: ...ng the lamp remove old lamp first 3 Reach in and using a cloth or napkin hold the bulb and pull out of the lamp socket located inside the reflector 4 Replace with a new lamp 5 Replace lamp cover align the screw holes and fasten the thumbscrews Mounting ORIENTATION This fixture may be mounted in any position provided there is adequate room for ventilation RIGGING It is important never to obstruct t...

Page 6: ... of a relay system for remote switching or to go with DMX control use the latest in DMX compatible Dimmer Relay Pack all available from CHAUVET A relay system will allow you to remotely trigger the Duo Moons and any other non dimmable effect light from a switch panel Make sure to use a cable of at least 25 feet to provide ample distance between the control panel and the switch pack for most mobile...

Page 7: ...s on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the unit s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prep...

Page 8: ...ely in order to measure correctly check to see if perhaps it is stuck Fogger or Snow output has dropped Clean with distilled water and vinegar Replace hose Lamps cuts off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick s...

Page 9: ...ent draw peak 190W 120V LAMPS BRL x 2 50W 12V THERMAL Maximum ambient temperature 40 104 F FUSE Main 20mm Glass 3A 250V Fast Blow PCB 20mm Glass 3A 250V Fast Blow ORDERING INFORMATION Duo Moons CH 160A Fuse 3A P170FUSE003 Technical Support Address Service Dept 3000 N 29th Ct Hollywood FL 33020 U S A Support Email tech chauvetlighting com Telephone 954 929 1115 Press 4 Fax 954 929 5560 Attention Se...