Page 7 of 53
VIP Drive 10-5 Nova User Manual Rev. 1
Setup
3. Setup
AC Power
The VIP Drive 10-5 Nova has an auto-ranging power supply and it can work with an input voltage range of
100 to 240 VAC, 50/60 Hz.
To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current
value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart.
The listed current rating indicates the product’s average current draw under normal conditions.
AC Plug
The VIP Drive 10-5 Nova comes with a power input cord terminated with an IEC connector on one end and
an Edison plug on the other end (U.S. market). If the power input cord that came with your product has no
plug, or if you need to change the plug, use the table below to wire the new plug.
Mounting
The VIP Drive 10-5 Nova fits nicely on a standard 19” rack, or it can be placed on its rubber feet on a flat
level surface.
Signal Connections
The VIP Drive 10-5 Nova uses the NOVA control protocol to send video signal to the connected panels.
The VIP Drive 10-5 Nova has USB and Ethernet ports for interfacing with a computer, HDMI, DVI, SDI and
fiber optic ports for sending/receiving at distance, as well as 10 RJ45 out ports and GenLock in and loop
connectors.
Video Source Connection
You can link the VIP Drive 10-5 Nova directly to a video source using a DVI connection, an HDMI
connection, or an SDI connection.
NovaLCT Connection
You can link the VIP Drive 10-5 Nova to a computer running the NovaLCT software using a USB (type A
or B) connection or an ethernet cable. This will provide control options for the VIP Drive 10-5 Nova through
a computer interface.
•
Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure
the product has an appropriate electrical ground to avoid the risk of electrocution or
fire.
•
To eliminate unnecessary wear and improve its lifespan, during periods of non-use
completely disconnect the product from power via breaker or by unplugging it.
Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the
rheostat or dimmer channel serves only as a 0 to 100% switch.
Connection
Wire (U.S.)
Wire (Europe)
Screw Color
AC Live
Black
Brown
Yellow or Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green