![Chase CONCRETE FINISH Installation Manual Download Page 43](http://html1.mh-extra.com/html/chase/concrete-finish/concrete-finish_installation-manual_2592056043.webp)
41
7.12 Window Head
FIXING WASHER AND SCREW
NOTE: SCREWS TO BE MIN
25 MM DEPTH INTO STUD
RENDER/MESH/TEXTURE
CHASE EPS PANEL
BREATHABLE WALL WRAP
WALL LINING
EXTERNAL CORNER BEAD
SPECIFIED WINDOW
SYSTEM
FRAMING AS SPECIFIED
ADDITIONAL WALL INSULATION
AS SPECIFIED
LINTEL AS SPECIFIED
PACKER AS SPECIFIED
ARCHITRAVE AS SPECIFIED
FLASHING TAPE
REVEAL AS SPECIFIED
SEALANT (BY BUILDER)
Issue Description
Revisions
Notes
Drawing Number
Issue
Scale
Drawing Name
System Name
Date
1 : 5 @ A4
0
0
VERSION
CP-018
TYPICAL WINDOW HEAD DETAIL
FOR CAVITY SYSTEM
05-05-20
CHASE EPS PANEL
EXTERNAL WALL CLADDING SYSTEM
NOTE:
REQUIREMENTS FOR SEALANT AROUND
WINDOWS MAY VARY BY THE TYPE OF WINDOW.
PLEASE REFER TO WINDOW MANUFACTURER FOR SEALANT
REQUIREMETS.
BATTEN FOR CAVITY SYSTEM
41
RENDER/MESH/TEXTURE
CHASE EPS PANEL
BREATHABLE WALL WRAP
FIXING WASHER & SCREW
NOTE: SCREWS TO BE
MIN 25 MM DEPTH INTO STUD
ADDITIONAL WALL INSULATION
AS SPECIFIED
WALL LINING
EXTERNAL CORNER BEAD
EXPANDING FOAM
0
VERSION
10-05-16
FIXING WASHER AND SCREW
NOTE: SCREWS TO BE MIN
25 MM DEPTH INTO STUD
RENDER/MESH/TEXTURE
CHASE EPS PANEL
BREATHABLE WALL WRAP
WALL LINING
EXTERNAL CORNER BEAD
SPECIFIED WINDOW
SYSTEM
FRAMING AS SPECIFIED
ADDITIONAL WALL INSULATION
AS SPECIFIED
LINTEL AS SPECIFIED
PACKER AS SPECIFIED
ARCHITRAVE AS SPECIFIED
FLASHING TAPE
REVEAL AS SPECIFIED
SEALANT (BY BUILDER)
0
VERSION
04-06-18
NOTE:
REQUIREMENTS FOR SEALANT AROUND
WINDOWS MAY VARY BY THE TYPE OF WINDOW.
PLEASE REFER TO WINDOW MANUFACTURER FOR SEALANT
REQUIREMETS.
7.12 Window Head
RENDER/MESH/TEXTURE
CHASE EPS PANEL
BREATHABLE WALL WRAP
EXTERNAL CORNER BEAD
SPECIFIED WINDOW SYSTEM
WALL LINING
FLASHING TAPE
REVEAL AS SPECIFIED
ARCHITRAVE AS SPECIFIED
SEALANT (BY BUILDER)
0
VERSION
04-06-18
NOTE:
REQUIREMENTS FOR SEALANT AROUND
WINDOWS MAY VARY BY THE TYPE OF WINDOW.
PLEASE REFER TO WINDOW MANUFACTURER FOR SEALANT
REQUIREMETS.
TYPICAL WINDOW HEAD DETAIL - DIRECT FIX
TYPICAL WINDOW HEAD DETAIL - CAVITY SYSTEM
Summary of Contents for CONCRETE FINISH
Page 4: ...2 1 Introduction...
Page 6: ...4 2 System Summary...
Page 9: ...7...
Page 10: ...8 3 National Construction Code NCC 2019...
Page 14: ...12 4 Materials...
Page 20: ...18 5 Specifications...
Page 22: ...20 6 Installation...
Page 29: ...27 Notes...
Page 30: ...28 7 Construction Details...