INSTALLATION INSTRUCTIONS
FITTING THE CONVECTION CASING, FLUE
PIPE AND STOVE
Having prepared the fireplace as described, the convection case,
stove and flue pipe can now be fitted.
1. ATTACH FLUE COLLAR TO THE FLUE PIPE
Some liner manufacturers recommended the use of a rigid pipe with
the liner - please refer to the liner manufacturers instructions. Fix the
upper flue collar to the flue pipe through the screw holes in the side
of the ring. The flue collar can be attached at any of 4 positions
depending on the required angle of the flue.
It is vital that the connections at both ends of the flue pipe are well
sealed. The flue pipe and collar can be sealed with fire cement
and/or a gasket.
2. INSERT THE CONVECTION CASING INTO THE OPENING
Make sure the four self-clinching studs are in the holes in the flue
collar, pointing downwards. Slide the convection casing into position
in the opening until the flue outlet lines up with the flue pipe. Any
excess air ducting still in the opening can be pulled out at the
external termination point and trimmed to fit the grille selected.
Ensure that the air supply duct is not kinked during the fitting
process.
1. Attach flue collar to length of flexible flue liner
3. MAKE FLUE CONNECTION
Reaching through the flue outlet, bring the flue collar down through the outlet
until the studs line up with the four holes in the convection casing. Use nuts to
secure the studs into place.
14
Upper flue collar
Convection casing
Flue pipe
Sealed with gasket
Upper flue collar
Flue liner
Self-clinching studs
Fix collar to flue with
screws either side
Collar can be positioned as necessary
depending on required angle of flue
2. Insert convection casing into opening