Place Control Panel Assembly onto Smoker Chamber by placing tabs under the front edge of the Smoker Chamber. The
Control valve must engage the burner venturi tube as shown
A
.
•
From the inside of the Smoker Chamber, Install 2 #10-24x3/8” screws through the smoker chamber and through the
Control panel Tabs as shown. Thread 1 #10-24 Keps Nut onto each screw and tighten As shown
B.
Install 2 #10-24x3/8”
screws through the control panel tabs and into the burner assembly housing. Thread 1 #10-24 Keps Nut onto each screw
and tighten securely.
Shown B
A
Qty: 4
#10-24 Keps Nut
Qty: 4
#10-24x3/8" Screw
Control
Panel Tabs
Control
Valve
B
#10-24x3/8" Screws
NOTE: Hose not shown
for clarity
Control Panel
Shown Installed
•
Be sure the electrode wire exits the hole UNDER the venturi tube hole. DO NOT route the wire through the same hole as
the burner venturi tube.
•
Install Ignitor Wire by pushing the round connector onto the Ignitor as shown.
Push the
Round end
of ignitor wire
onto the
Rotary Ignitor
Route wire
through
hole under the
Venturi Tube
Hole
Rotary ignitor
Control Panel
Screw Hole
Burner Assembly
Housing
Install 1 #10-24x3/8"
Screw per side