18  •  10201597-50

EMERGENCIES:

 If a gas leak cannot be stopped, or a fire occurs due to gas leakage, call the fire department.

Emergencies

Problem

Gas leaking from 
cracked/cut/burned 
hose.

Gas leaking from LP 
cylinder.

Gas leaking from LP 
cylinder valve.

Gas leaking between 
LP cylinder and 
regulator connection.

Fire coming through 
control panel.

Grease fire or 
continuous excessive 
flames above cooking 
surface.

Burner will not  light 
using ignitor.

Possible Cause

Possible Cause

• Damaged hose.

• Mechanical failure due to rusting or 

mishandling.

• Failure of cylinder valve from 

mishandling or mechanical failure.

• Improper installation, connection not 

tight, failure of rubber seal.

• Fire in burner tube section of burner due 

to blockage.

• Too much grease buildup in burner area.

GAS ISSUES:

• Burner not engaged with control valve.

• Obstruction in burner.

• No gas flow.

• Vapor lock at coupling nut to LP cylinder.

• Coupling nut and LP cylinder valve not 

fully connected.

ELECTRICAL ISSUES:

• Electrode cracked or broken; “sparks at 

crack.”

• Electrode tip not in proper position

• Wire and/or electrode covered with 

cooking residue.

• Wire is loose or disconnected.

• Wire is shorting (sparking) between 

ignitor and electrode.

Prevention/Solution

Prevention/Solution

• Turn off gas at LP cylinder or at source on natural gas systems. If 

hose is cut or cracked, replace valve/hose/regulator. See LP 
Cylinder Leak Test and Connecting Regulator to the LP Cylinder.

• Replace LP cylinder.

• Turn off LP cylinder valve. Return LP cylinder to gas supplier.

• Turn off LP cylinder valve. Remove regulator from cylinder and 

visually inspect rubber seal for damage. See LP Cylinder Leak Test 
and Connecting Regulator to the LP Cylinder.

• Turn off control knob and LP cylinder valve. Allow flames to die 

down. After fire is out and fryer is cold, remove burner and inspect 
for spider nests or rust. See Natural Hazard and Cleaning the 
Burner Assembly pages.

• Turn off control knobs and LP cylinder valve. Allow flames to die 

down. After cooling, clean food particles and excess grease from 
inside fryer body, grease tray, and other surfaces.

• Make sure valve is positioned inside of burner tube.

• Ensure burner tube is not obstructed with spider webs or other 

matter. See cleaning section of Use and Care.

• Make sure LP cylinder is not empty. If LP cylinder is not empty, 

refer to “Sudden drop in gas flow.”

• Turn off knob and disconnect coupling nut from LP cylinder. 

Reconnect and retry.

• Turn the coupling nut approximately one-half to three-quarters 

additional turn until solid stop. Tighten by hand only - do not use 
tools.

• Replace electrode.

• Tip of electrode should be pointing toward gas port opening on 

burner. The distance should be 1/8” to 1/4”. Adjust if necessary.

• Clean wire and/or electrode with rubbing alcohol and clean swab.

• Reconnect wire or replace electrode/wire assembly.

• Replace ignitor wire/electrode assembly.

Troubleshooting

Summary of Contents for CB00X 10201597

Page 1: ...sumer CONSUMER Keep this manual for future reference Failure to follow all manufacturer s instructions could result in serious personal injury and or property damage Some parts may contain sharp edges especially as noted in the manual Wear protective gloves if necessary CAUTION WARNING 42804691 04 01 10 Product Manual Model 10201597 50 CAUTION CAUTION THIS UNIT IS HEAVY DO NOT assemble without a h...

Page 2: ...must conform with local codes or in their absence of local codes with either the National Fuel Gas Code ANSI Z223 1 NFPA 54 Natural Gas and Propane Installation Code CSA B149 1 and Propane Storage and Handling CSA B149 2 Canadian Electrical Code CSA C22 1 or the Standard for Recreational Vehicles ANSI A 119 2 NFPA 1192 and CSA Z240 RV Series Recreational Vehicle Code as applicable Your CB600x is n...

Page 3: ...rcial Series Designer Series Diamond Flame Double Chef Everybody Outside FastStart FlavorMaster Front Avenue Grill 2 Go Advantage Grill 2 Go Ice Hog and Yard Bird H20 Smoker Infrared Grilling s Juicy Little Secret Incredible Taste Infallible Results Infrared Inside Let s Grill Something Together Longhorn Precision Flame Quick2Burn QuickSet Ready When You Are Season Set And Savor Sizzle On The Gril...

Page 4: ...r grill must meet the following requirements Use LP cylinders only with these required measurements 12 30 5cm diameter x 18 45 7 cm tall with 20 lb 9 kg capacity maximum LP cylinders must be constructed and marked in accordance with specifications for LP cylinders of the U S Department of Transportation DOT or for Canada CAN CSA B339 cylinders spheres and tubes for transportation of dangerous good...

Page 5: ...inder as described in the LP Cylinder section of this manual Always keep new and exchanged LP cylinders in upright position during use transit or storage Leak test new and exchanged LP cylinders BEFORE connecting to grill LP Cylinder Leak Test For your safety Leak test must be repeated each time LP cylinder is exchanged or refilled Do not smoke during leak test Do not use an open flame to check fo...

Page 6: ...alve by turning hand wheel counterclockwise If you hear a rushing sound turn gas off immediately There is a major leak at the connection Correct before proceeding 4 Brush soapy solution onto areas circled below 5 If growing bubbles appear there is a leak Close LP cylinder valve immediately and retighten connections If leaks cannot be stopped do not try to repair Call for replacement parts Order ne...

Page 7: ... of ignition such as pilot lights on water heaters live electrical appliances etc appliance Apartment Dwellers Check with management to learn the requirements and fire codes for using an LP gas appliance in your apartment complex If allowed use outside on the ground floor with a three 3 foot clearance from walls or rails Do not use on or under balconies NEVER attempt to light burner with any type ...

Page 8: ...ution of detergent and water or use a grill cleaner with scrub brush on insides of appliance lid and bottom Rinse and allow to completely air dry Do not apply a caustic grill oven cleaner to painted surfaces Plastic parts Wash with warm soapy water and wipe dry Do not use citrisol abrasive cleaners degreasers or a concentrated grill cleaner on plastic parts Damage to and failure of parts can resul...

Page 9: ...ts have been known to create flashback problems The spiders spin webs build nests and lay eggs in the grill s venturi tube s obstructing the flow of gas to the burner The backed up gas can ignite in the venturi behind the control panel This is known as a flashback and it can damage your grill and even cause injury To prevent flashbacks and ensure good performance the burner and venturi assembly sh...

Page 10: ...b steaks roasts and pork chops can be cooked to 160 F NEVER partially cook meat or poultry and finish cooking later Cook food completely to destroy harmful bacteria Storing Your Appliance Store in dry location When LP cylinder is connected to appliance store outdoors in a well ventilated space and out of reach of children If Regulator is disconnected from the LP cylinder a hook is provided to hang...

Page 11: ...e initial amount of hot water added 4 quarts should last 4 6 hours After 4 6 hours check water level and add more hot water as necessary Use a meat thermometer for measuring the internal heat of any food The appearance of smoked foods resembles no other method of cooking particularly in light colored meats such as pork turkey chicken and Cornish hens The outside will be pinkish red while the insid...

Page 12: ...S 2 WIRE RACK SMOKER CHAMBER T 1 WIRE ELECTRODE 1 HARDWARE PACK 1 ASSEMBLY INSTRUCTIONS ENGLISH 1 ASSEMBLY INSTRUCTIONS SPANISH NOTE Some grill parts shown in the assembly steps may differ slightly in appearance from those on your particular model However the method of assembly remains the same F M1 D G I A B H J K Q L C S N O P R 12 10201597 50 T E M2 M1 M1 M2 M2 M2 Hardware List Item Description...

Page 13: ...ening facing up Swing Door open then lift up and Remove the door from its hinges CAUTION THIS UNIT IS HEAVY DO NOT ASSEMBLE WITHOUT A HELPER TOP Install Burner Housing to Smoker Chamber using three 1 4 20x1 2 bolts Install all bolts hand tight then tighten with a 2 phillips screwdriver not provided NOTE The venturi tube MUST face up towards the door opening Qty 3 1 4 20x1 2 Combo Truss head screw ...

Page 14: ...ssembly housing Thread 1 10 24 Keps Nut onto each screw and tighten securely Shown B A Qty 4 10 24 Keps Nut Qty 4 10 24x3 8 Screw Control Panel Tabs Control Valve B 10 24x3 8 Screws NOTE Hose not shown for clarity Control Panel Shown Installed Be sure the electrode wire exits the hole UNDER the venturi tube hole DO NOT route the wire through the same hole as the burner venturi tube Install Ignitor...

Page 15: ...right on its legs CAUTION This unit is HEAVY Do not attempt this step without assistance Leg with Rating Label Install legs by placing 2 1 4 20x1 2 Hex Head Bolt through the smoker body and through each leg as shown Thread the bolts into the 1 4 20 nut welded to the underside of each leg Tighten bolts by hand Using an adjustable wrench not provided tighten each bolt securely Install the leg with t...

Page 16: ...20 Keps nuts Tighten securely Place the Water Pan onto the drawer rack as shown Slide the Drawer with Water Pan into the Smoker body Qty 1 1 4 20 Nut Qty 1 1 4 20x1 2 Hex Head Bolt Qty 2 1 4 Flat Washer A B C Damper shown installed Insert 1 4 20X1 2 bolt and flat washer into bolt hole Insert damper handle through damper hole as shown Install Side Handles with 1 4 20X3 4 bolts and 1 4 20 Keps nuts ...

Page 17: ...nut to the Thermometer Insert the 3 Cooking Grates into the smoker body Slip the edge of the Top Grate under the Damper Handle A Then carefully align the grate so that the wire ends fit into the holes in the Smoker Body top B Carefully place the door back onto the Smoker Body hinges A Top Grate Cooking Grates 3 B Thermometer Wing Nut ...

Page 18: ...ve hose regulator See LP Cylinder Leak Test and Connecting Regulator to the LP Cylinder Replace LP cylinder Turn off LP cylinder valve Return LP cylinder to gas supplier Turn off LP cylinder valve Remove regulator from cylinder and visually inspect rubber seal for damage See LP Cylinder Leak Test and Connecting Regulator to the LP Cylinder Turn off control knob and LP cylinder valve Allow flames t...

Page 19: ...gulator Reconnect regulator and leak test Turn on LP cylinder valve wait 30 seconds and then light fryer Turn off knob and LP cylinder valve Disconnect coupling nut from cylinder Reconnect and retry Refill LP cylinder Refer to Sudden drop in gas flow above Clean burner and inside of fryer body Trim fat from meat before grilling Adjust lower temperature accordingly Turn knob to OFF Turn gas off at ...

Page 20: ...e breach of either this limited warranty or any applicable implied warranty or for failure or damage resulting from acts of God improper care and maintenance grease fire accident alteration replacement of parts by anyone other than Manufacturer misuse transportation commercial use abuse hostile environments inclement weather acts of nature animal tampering improper installation or installation not...

Page 21: ...e breach of either this limited warranty or any applicable implied warranty or for failure or damage resulting from acts of God improper care and maintenance grease fire accident alteration replacement of parts by anyone other than Manufacturer misuse transportation commercial use abuse hostile environments inclement weather acts of nature animal tampering improper installation or installation not...

Page 22: ...22 10201597 50 NOTES ...

Page 23: ...REGTEMP REV02 Warranty Registration Department P O Box 1240 Columbus GA 31902 1240 ...

Page 24: ......

Reviews: