100430 - 6500W ELECTRIC START GENERATOR
SPECIFICATIONS
31
SPECIFICATIONS
Generator Specifications
Generator Model
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
100430
Start Type
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electric, Manual
Watts (Starting/Running)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8125/6500
AC Volts
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
120/240
AC Amps @ 120V (Running)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
54.2
AC Amps @ 120/240V (Running)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27.1
Frequency
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
60 Hz
Phase
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single
Grounding Type
. . . . . . . . . . . . . . . . . . . . . . . . . .
Neutral Bonded to Frame
Weight
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
220 lb. (99.6 kg)
Length
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
32.4 in. (82.3 cm)
Width
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27.8 in. (70.7 cm)
Height
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
31.5 in. (80 cm)
Engine Specifications
Model
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
YF188IG
Displacement
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
389 cc
Type
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-Stroke OHV
Spark Plug
OEM Type
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NHSP F6RTC
Replacement Type
. . . . . . . . . . . . . . . . . . . . . .
NGK BPR6ES or equivalent
Gap
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
0.028-0.031 in. (0.7-0.8 mm)
Valve
Intake Clearance
. . . . . . . . . . . . . . . . .
0.005-0.007 in. (0.13-0.17 mm)
Exhaust Clearance
. . . . . . . . . . . . . . .
0.007-0.009 in. (0.18-0.22 mm)
NOTICE
A technical bulletin regarding valve adjustment procedures is
available at www.championpowerequipment.com.
Oil Specifications
DO NOT OVERFILL.
Type
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
*See following chart
Capacity
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
37.2 fl. oz. (1100 ml)
-20
0
20
40
60
Ambient temperature
Recommended Engine Oil Type
80
100
120
-28.9
°F
°C
-17.8
-6.7
4.4
15.6
26.7
37.8
48.9
10W-30
5W-30 Full Synthetic
10W-40
5W-30
NOTICE
Temperature will affect engine oil and engine performance.
Change the type of engine oil used based on temperature
shown in the
“Recommended Engine Oil Type”
table.
Fuel Specifications
Use unleaded gasoline with a minimum octane rating of 87 and
an ethanol content of 10% or less by volume. DO NOT USE E15 or
E85. DO NOT OVERFILL.
Gasoline Capacity
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.5 gal. (32.00 L)
Battery Specifications
Type
. . . . . . . . . . . . . . . . . . . . . . .
Rechargeable, Non-Spillable Lead Acid
Volts DC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12
Capacity
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 Ah
Temperature Specifications
Starting Temperature Range (°F/°C)
. . . . . . . . . . .
5 to 104/-15 to 40
NOTICE
An important message about temperature:
Your product
is designed and rated for continuous operation at ambient
temperatures up to 104°F (40°C). When needed, it may be
operated at temperatures ranging from 5°F (-15°C) to 122°F
(50°C) for short periods of time. If exposed to temperatures
outside this range during storage, it should be brought back
within this range before operation. In any event, the product
must always be operated outdoors, in a well-ventilated area
and away from doors, windows and vents.