100430 - 6500W ELECTRIC START GENERATOR
OPERATION
21
NOTICE
This blinking LED light does not indicate CO Shield
®
is working,
as CO Shield
®
is working at all times when the generator
is running. Also, the LED light will not blink (10) times if the
generator was restarted within 1 minute after it was manually
shut off. This does not occur if generator shut off from a high
CO event.
If CO Shield
®
system experiences a fault and no longer provides
protection, the generator is shutoff automatically and the
yellow
LED light will blink for at least five (5) minutes to notify you of the
fault.
AUTOMATIC SHUTOFF
SEE ACTION LABEL
Apagado automático
Vea etiqueta de acción
ARRÊT AUTOMATIQUE
VOIR L'ÉTIQUETTE D'ACTION
SERVICE
Realice un servicio
EFFECTUER L’ENTRETIEN
Call our Technical Support Team at 1-877-338-0999 for repair.
The generator can be restarted, but will continue to shutoff.
NOTICE
CO Shield
®
will detect the accumulation of carbon monoxide
(CO) from other fuel burning sources such as engine powered
equipment, or propane heaters used in the area of operation. If
another generator is used and the exhaust stream is pointed at
a CO Shield
®
equipped generator, the CO Shield
®
may initiate
a shutoff due to rising carbon monoxide (CO) levels. This is not
a fault. Poisonous carbon monoxide (CO) has been detected.
You must take action to move and direct the generator exhaust
stream to better disperse carbon monoxide (CO) far away from
people or buildings.
DANGER
Tampering with the CO Shield
®
system will result in a
hazardous condition and will void your warranty.
Removing the CO Shield
®
module will not allow the generator
to start.
Generator Location
WARNING
NEVER operate the generator inside any building, garage,
basement, crawlspace, shed, enclosure or compartment,
including a generator compartment of a recreational vehicle.
NEVER operate or start the generator in the back of an
SUV, camper, trailer, truck bed (regular sides, flat or other
configuration), under staircases, stairwells, next to walls
or buildings or in any other location that will not allow for
adequate cooling of the generator or for the proper exit of the
exhaust flow from the muffler system.
DO NOT operate or store the generator in wet weather
conditions such as rain or snow. Using a generator in wet
conditions could result in serious injury or death due to
electrocution.
In some state’s generators may be required to be registered
with the local utility company when used at construction sites
and may be subject to additional rules and regulations, consult
your local municipal authority.
Generators should always be operated on a flat, level surface
at all times (even when not in operation).
Generators must have a minimum of 5 feet (1.5 m) of
clearance from all combustible material.
Generators must also have a minimum of 3 feet (91.4 cm)
of air flow clearance on all sides to allow for adequate
performance cooling, maintenance and servicing.
Always place the generator in a well-ventilated area. NEVER
place the generator near air intake vents or where exhaust
fumes could be drawn into occupied or confined spaces.
Always carefully consider wind and air currents when
positioning generator.
Always allow generators to properly cool before transport or
for storage purposes.
Failure to follow proper safety precautions may result in
personal injury, damage to the generator and void the
manufacturer’s warranty.
WARNING
During operation the muffler and exhaust fumes will become
hot. If adequate cooling and breathing space are not supplied,
or if the generator is blocked or enclosed, temperatures can
become extremely heated and may lead to fire.