Wash Tank Heater and High Limit Thermostat
The wash tank heater is mounted on the side wall in the bottom of the tank. It maintains the
wash tank temperature at a minimum of 160˚F/70˚C. The heater is protected from a low water
condition by a surface mounted high limit switch.
Check the high limit thermostat before replacing a suspected heater:
1. Flip the power toggle switch to off.
2. Turn off the main incoming power.
3. Remove the lower left hand side panel.
4. Push the manual reset on the high limit.
Pull one lead from the high limit and check
for continuity. Replace if open.
5. Apply a coating of heat sink compound,
P/N 110563, to the high limit before
mounting to base.
To replace wash tank heater:
1. Perform steps 1-5 from above.
2. Open the front door and remove the
lower spray arms.
3. Remove the scrap screens amd pump
intake strainer. (See Fig 12 for
element location in tank).
4. From the outside bottom of tank,
disconnect the heater wires and remove the
retaining nuts. (See Fig 13 for the
rear view of the machine).
5. Remove the element from the inside of the tank.
6. Apply gasket to element and insert into tank.
7. Install retaining nuts.
8. Reconnect heater wires.
9. Replace panel.
10. Restore power to machine.
11. Check for leaks and proper operation.
Element
Element
Figure 14
Rear View of High Limit
High
Limit
Element
Summary of Contents for PP-28 Corner
Page 4: ...REVISION RECORD CONT REVISIONS ii ...
Page 43: ...35 REPLACEMENT PARTS REPLACEMENT PARTS ...
Page 44: ...36 REPLACEMENT PARTS 5 2 5 1 5 4 3 5 5 5 6 9 7 10 11 12 A B A A 8 Figure 22 Panels ...
Page 48: ...40 REPLACEMENT PARTS 2 1 1 3 6 7 3 5 4 A A A 8 9 10 B B B Figure 24 Cable Pulley Assembly ...
Page 50: ...42 REPLACEMENT PARTS 2 3 3 4 8 7 6 5 3 5 5 5 3 9 10 1 11 12 Figure 25 Counterweight System ...
Page 64: ...56 REPLACEMENT PARTS 2 3 6 4 5 1 7 Figure 32 Scrap Screens Baskets ...
Page 75: ...67 REPLACEMENT PARTS THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 83: ...75 REPLACEMENT PARTS THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 84: ...76 REPLACEMENT PARTS 3 5 6 4 5 5 5 1 2 5 3 Figure 40 Side Mount Booster Cabinet ...
Page 86: ...78 REPLACEMENT PARTS 1 2 3 4 7 8 6 9 10 4 11 12 13 5 Figure 41 Pump Assembly ...
Page 88: ...80 REPLACEMENT PARTS 3 4 5 6 7 8 10 1 2 9 11 11 Figure 42 Machine Control Panel ...
Page 94: ...86 REPLACEMENT PARTS 0 1 2 1 2 3 4 6 7 8 5 Figure 45 Vent Fan Control Cabinet Optional ...
Page 98: ...90 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 99: ...91 ELECTRICAL SCHEMATICS ELECTRICAL SCHEMATICS ...
Page 103: ...98 ...
Page 104: ...99 ...
Page 105: ......