100892 - 4500W OPEN FRAME INvERTER
OPERATION
21
CAUTION
For periods of high electrical load or momentary fluctuations,
the Eco Mode should be off.
12v DC Automotive Style Outlet
The 12V DC outlet(s) can be used with supplied accessories.
The DC output is unregulated and can damage some products.
Confirm the input voltage range of your item is at least 12-24V DC.
When using the DC outlet turn the Eco Mode switch to the “OFF”
position.
WARNING
Do not operate a device while it is plugged in to the 12V DC
outlet.
Prolonged exposure to engine exhaust can cause serious injury
or death.
CAUTION
While charging a device do not place on the exhaust side of the
generator. Extreme heat caused by exhaust can damage the
device, and cause a potential fire hazard.
Battery Charging
1. Before connecting the battery charging cable (included) to a
battery that is installed in a vehicle, disconnect the vehicle
battery ground cable from the negative (–) battery terminal.
2. Plug the battery charging cable into the 12V DC receptacle of
the generator.
3. Connect the red (+) battery charger lead to the red (+) battery
terminal.
4. Connect the black (–) battery charger lead to the black (–)
battery terminal.
5. Start the generator.
CAUTION
Do not start the vehicle while the battery charging cable is
connected and the generator is running. It will not give the
battery a boost of power. The vehicle or the generator may
be damaged. Charge only vented wet lead acid batteries.
Other types of batteries may burst, causing personal injury or
damage.
NOTICE
Be sure all electric devices including the lines and plug
connections are in good condition before connection to the
generator.
Parallel Operation
The Champion model 100892 is parallel ready and can be
operated in parallel with another Champion unit to increase the
total available electrical power. A Champion model 100319 parallel
kit (sold separately) is required for parallel operation. For a list of
compatible models or to order a parallel kit, please call customer
service at 1-877-338-0999 or visit
www.championpowerequipment.com.
Detailed instructions for parallel kit installation and operation of
the connected generators are provided in the parallel kit operator’s
manual.
Stopping the Engine
1. Turn off and unplug all electrical loads. Never start or stop the
generator with electrical devices plugged in or turned on.
2. Let the generator run at no-load for several minutes to
stabilize internal temperatures of the engine and generator.
3. Turn the fuel valve to the “OFF” position.
4. Let the engine run until fuel starvation has stopped the
engine. This usually takes a few minutes.
5. Press the engine switch to the “OFF” position.
Important:
Always ensure that the fuel valve and the engine
switch are in the “OFF” position when the generator is not in use.