100544 - 7000W DUAL FUEL GENERATOR
STORAGE
30
EVERY 100 HOURS OR EVERY SEASON
#
Change oil
#
Clean/adjust spark plug
#
Check/adjust valve clearance*
#
Clean spark arrestor
#
Clean fuel tank and filter*
EVERY 250 HOURS
#
Clean combustion chamber*
EVERY 3 YEARS
#
Replace fuel line*
#
Replace LPG hose
* To be performed by knowledgeable, experienced owners or CPE certified
service centers.
STORAGE
!
DANGER
Gasoline, gasoline vapors and propane (LPG) are highly
flammable and extremely explosive.
Fire or explosion can cause severe burns or death. Only
fill or drain fuel outdoors in a well-ventilated area. DO NOT
pump gasoline directly into the generator. Use an approved
container to transfer the fuel to the generator. Never use a
gasoline container, gasoline tank, LPG connector hose, LPG
cylinder or any other fuel item that is damaged or appears
damaged. DO NOT overfill the gasoline tank. Always keep
fuel away from sparks, open flames, pilot lights, heat and
other sources of ignition. DO NOT light or smoke cigarettes.
"
NOTICE
If no gasoline has been added to the generator, the gasoline
tank and carburetor drainage steps may be skipped.
Short Term Storage (up to 1 year)
Gasoline in the gasoline tank has a maximum shelf life of up to
1 year with the addition of properly formulated fuel stabilizers
and if stored in a cool, dry place. Gasoline in the carburetor,
however, may gum up and clog the carburetor if it isn’t used or
drained within 2-4 weeks.
1. Be sure all appliances are disconnected from the generator.
2. Add a properly formulated fuel stabilizer to the gasoline
tank.
3. Turn the fuel select dial to gasoline.
4. Start and run the generator for 10 minutes so the treated
gasoline cycles through the fuel system and carburetor.
5. Turn fuel selection dial to the “OFF” position.
6. Remove the spark plug cap and spark plug and pour about
a tablespoon of oil into the cylinder.
7. Pull the recoil slowly to crank the engine to distribute the
oil and lubricate the cylinder.
8. Reattach the spark plug and spark plug cap.
9. If the generator includes a battery, disconnect and charge
according to
Generator Battery
.
10. Clean the generator according to
Cleaning the Generator
.
11. Store the generator in a cool, dry place out of direct
sunlight.
Long Term Storage (over 1 year)
For storage over 1 year, the gasoline tank and carburetor must
be completely drained of gasoline.
1. On the side operator panel, rotate the fuel selector dial to
GASOLINE.
2. Remove the carburetor drain bolt to empty gasoline from
the tank and carburetor into an appropriate container. Use
a funnel or appropriate hose if necessary to avoid spillage.
3. When empty, replace and tighten carburetor drain bolt.
Dispose of gasoline according to local regulations or
guidelines.
4. Rotate the fuel selector dial to the OFF position.
5. Follow steps 7-12 according to Short Term Storage
procedure.