BEFORE YOU BEGIN

Leave room on the side of the motor for arms and installation work. Make sure to leave sufficient space.

Windload:

Even light wind may cause the motor to reverse (safety-reverse) as the forces effecting the gate are very high. This applies especially

to solid panel gates.

Note: An E-lock in combination with a floor locking device should always be installed in order to relieve the motor. In extreme cases strong wind
may bend fittings and door and /or damage the motor .

There are many important factors when deciding on the correct motor. Assuming a well functioning gate, the initial force is the most difficult
moment. When the gate is moving it generally requires a considerably smaller amount of force.

Gate Size:  

Gate size is an important factor. Wind can slow down gate or distort it, leading to higher amount of required  force.

Gate weight:  

Specification of gate weight represents only a rough parameter, which can vary according to actual  demand. Operation is

important.

Influence of temperature:

Low outdoor temperatures can impede or even prevent starting torque (ground deformation etc.). High outdoor

temperatures can lead to premature initiation of temperature protection (approx. 135°)

Attention:

Motors are not designed to run continuously (continuous operation). The motor warms up and can reach a temperature at which it

shuts down until operating temperature is reached again. Outside temperature and gate represent important parameters for actual operating
duration.

3x

Optional accessories

1.

Flashing lamp

2. ECK7

 

3.. Pfeilerbeschl

4. Padlock

5.

. E

-lock

6. Trafo f

or E-lock

FLA1-LED

Kit for cable extension of one

 

installation unit. Consists of 

m of 

cable 6-pole with identical colours, 

distribution box IP

44

, cable screw joints

 

and fastening material

2 pieces with large 4-hole baseplate 

 041ASWG-0092, 041ASWG-0090

  55124VO (2 keys per lock)

 203285 (12 Volts)

    207399

203339 (in combination with E-lock)

203315 standard

     

203322 high

      

041ASWG-ANT

TX4RUNI

771REV

41REV

8747EML

2

3

4

5

6

7

8

12

13

1

10

7. Floor locking

8 Stops for gates

9. 

External antenna

10. 

Remote control

11. 

Photocells

12. 

Key switch

13. 

Wireless keypad

1

1

9

Summary of Contents for TPD10-05

Page 1: ...Mechanical electrical installation TPD10 05...

Page 2: ...xercise caution and do not wear rings watches or loose clothing Make sure that people who install maintain or operate the gate drive and or the control board are qualified and follow these instruction...

Page 3: ...d Operation is important Influence of temperature Low outdoor temperatures can impede or even prevent starting torque ground deformation etc High outdoor temperatures can lead to premature initiation...

Page 4: ...r and tear on the motor gate and fittings Operating a gate without fixed limit stops results in poor performance It is often dangerous leads to premature wear and voids your warranty 900 900 Max gate...

Page 5: ...adjusted INSTALLATION Instead of steel or plastic expanding anchors which are less suitable use adhesive composite anchors where a set screw is glued into brickwork free of stress With pillars made o...

Page 6: ...cure pin with R clip Turn release lever towards pillar Done The gate should now be slightly open This will be corrected during the learn cycle later on Note The hinge on the gate must be lubricated sl...

Page 7: ...pecifies that the closing forces at the gate edge must not exceed 400 N 40 kg for the last 500 mm before the door is CLOSED Above 500 mm the maximum force at the gate edge must not exceed 1400 N 140 k...

Page 8: ...nto fastening clips C Fasten transformer onto baseplate using the large screw and large washer D Put the 4 large closure screws through cover of the box Fasten 2 of them left or right approx 2cm into...

Page 9: ...erature 20 C 55 C Degree of protection IP54 WIRING OF CONTROL SUMMARY a start with still dead 230Volts supply cable on the left side of the box b Attach cable eye to ground wire Then connect ground wi...

Page 10: ...cells 2 e l o p e v i t a g e n M O C STOP 8 2KOhms connector for emergency switch or safety edge with 8 2KOhms E lock symbol connection for E lock control board INPUT 24VAC 24V power input from trans...

Page 11: ...xt to the transformer on to the baseplate using screws Open its casing and make all necessary electrical wiring Plug support board in to where the E lock symbol is depicted 30VDC MOTOR MASTER MOTOR SE...

Page 12: ...y edge causes the wings to reverse for one second FREE Factory setting is for 8 2 KOhms In this case safety edge must be installed or a 8 2 KOhms resistor must be connected LINKED used for emergency s...

Page 13: ...4 failed wait for the LEDs control board and remote control to go out Then start again with step 2 Up to 180 remote controls can be programmed likewise In case no remote control is to be be programmed...

Page 14: ...housing must not touch the gate Stop opening several times and check If housing touches the gate dimensions A B must be checked and if necessary underlay the gate pillar with flat washers in order to...

Page 15: ...or 2 starts closing automatically 7 Press P1 again SOFT STOP for wing motor 2 in CLOSE direction begins at this point 8 Press P1 again when CLOSE position is reached Now wing motor 1 starts automatica...

Page 16: ...Gate is rough running B Check if gate can be easily moved C Gate stopped through windload C Do not operate gate by windstorm D Reprogram travel to achieve sufficient level of fo 7x blinking Photocell...

Page 17: ...1 Programming remote control 2 Find and rectify fault s see description of LEDs 3 Check photocell connection programming 4 Check terminals and connections Control board does not work with transmitter...

Page 18: ......

Page 19: ......

Page 20: ...Chamberlain GmbH 2016 114A4623D en Chamberlain GmbH Alfred Nobel Strasse 4 66793 Saarwellingen Germany www chamberlain eu diy chamberlain eu...

Reviews: