background image

3

TIP: 

The area around the solar panel(s) 

should be clear of shadows or obstructions 
to the sun for a 180° arc east to west.

INSTALLATION

Solar panel(s) MUST be installed facing south. Use a compass to determine direction. Below are general instructions for installing the 
solar panel(s). Your installation may vary slightly depending on the solar panel purchased.
1.   Position the mounting bracket on the mounting surface. Mark and drill holes.
2.   Secure the solar panel to the mounting bracket using the hex bolts, hex nuts and washers provided.
3.   Secure the solar panel to the mounting surface using lag screws provided.

POSITION

The location of the panel(s) is critical to the success of the 
installation. In general, the panel(s) should be mounted using the 
provided angle bracket facing due south. The solar panel(s) should 
be mounted in an area clear of all obstructions and shade from 
buildings and trees. If the panel(s) is not casting a shadow, the 
battery is not being charged.

NOTE: 

Tall trees or buildings that do not shade the solar panel(s) 

in the summer could shade the solar panel(s) during the winter 
months when the sun sits lower in the sky.

Mounted Panel Must Face SOUTH

Mounting 
Surface

Mounting 
Surface

1

2

3

Hex Nut

Washer

Hex Bolt

MAXIMUM WIRE LENGTH (FEET)

AMERICAN 

WIRE GAUGE 

(AWG)

20 WATTS OF 

PANELS

40 WATTS OF 

PANELS

60 WATTS OF 

PANELS

16 

235 (71.6 m)

115 (35.1 m)

80 (24.4 m)

14

375 (114.3 m)

190 (57.9 m)

125 (38.1 m)

12

600 (182.9 m)

300 (91.4 m)

200 (61 m)

10

940 (286.5 m)

475 (144.8 m)

315 (96 m)

Chart

 assumes: copper wire, 65˚C, 5% drop, 30V nominal

Sun’s Position

South

180°

Winter Sun Height

Summer Sun Height

Up to 15°

South

TIP: 

To optimize the system for winter 

operation the angle can be increased an 
additional 15° (solar panel(s) sits more 
vertical).

Summary of Contents for SP10W12V

Page 1: ...12VDC RSL12U RSW12VDC RSW12U 7AH Not required Model K94 37236 Not required 5 6 33AH Not required Model K94 37236 Not required 5 6 LA400CONTU LA400VDC LA500CONTU LA500VDC 7AH Not required Model K94 372...

Page 2: ...are approximations Ratings vary based on gate construction installation and temperature Solar panels cannot be installed in areas that experience long periods of heavy fog lake effect snow or rain Re...

Page 3: ...t facing due south The solar panel s should be mounted in an area clear of all obstructions and shade from buildings and trees If the panel s is not casting a shadow the battery is not being charged N...

Page 4: ...qualified individual To BATT DC POWER input on control board 33AH BATTERIES IN SERIES 7AH BATTERIES IN SERIES A B C D A J15 Plug B Red wire for 33AH battery connections C Black wire for 33AH battery...

Page 5: ...ontrol board Fuse The remaining wires in the kit are not needed for 12V applications F Black jumper wire for two 7AH battery connections fuse E F B C To BATT DC POWER input on control board ONE 33AH B...

Page 6: ...PANELS 12V APPLICATIONS 10W APPLICATION IN PARALLEL 20W APPLICATION IN PARALLEL 30W APPLICATION IN PARALLEL 10W 10W 10W 10W 10W 10W 10W 20W 20W To Battery ies To Battery ies To Battery ies To Battery...

Page 7: ...rol Board Example WIRING WIRE THE SOLAR PANELS Models RSW12 RSL12 LA400 LA412 Follow all gate operator instructions for the maximum wattage and type of solar panels to be connected refer to your opera...

Page 8: ...llel with red wires connected to red wires and black wires connected to black wires OPERATOR POWERS UP BUT DOES NOT RUN PROPERLY 1 Batteries are not connected The system requires the batteries to run...

Page 9: ...Mod le K94 37236 non requis 4 6 33AH REQUIS Mod le K10 36183 Mod le K94 37236 non requis 4 6 RSL12VDC RSL12U RSW12VDC RSW12U 7AH non requis Mod le K94 37236 non requis 5 6 33AH non requis Mod le K94 3...

Page 10: ...ations Les taux varient en fonction de la construction et de l installation de la barri re et de la temp rature Les panneaux solaires ne peuvent pas tre install s dans des r gions o s vissent d pais b...

Page 11: ...ent pas d ombre la batterie ne se charge pas REMARQUE Les grands arbres ou difices qui ne cr ent pas d ombre sur les panneaux solaires en t pourraient en cr er pendant les mois d hiver lorsque le sol...

Page 12: ...ersonne qualifi e l entr e BATT DC POWER sur le tableau de commande l entr e BATT DC POWER sur le tableau de commande PILES 33AH EN S RIE PILES 7AH EN S RIE A B C D A B Fil rouge pour les connexions d...

Page 13: ...fils qui restent dans le n cessaire ne sont pas utilis s pour les applications de 12 V F Fil de liaison noir pour deux connexions de batterie 7AH E F B C l entr e BATT DC POWER sur le tableau de comm...

Page 14: ...20W 20W 20W le s pile s le s pile s le s pile s le s pile s le s pile s Mod les LA412CONTU LA412VDC RSL12VDC RSL12U RSW12VDC RSW12U Mod les LA400CONTU LA400VDC LA500CONTU LA500VDC LA500 CSL24VDC CSL24...

Page 15: ...s RSW12 RSL12 LA400 LA412 Suivre toutes les instructions de l op rateur de barri re concernant la puissance maximale et le type de panneaux solaires connecter consulter le manuel de votre op rateur 1...

Page 16: ...fils rouges et les fils noirs connect s aux fils noirs L OP RATEUR SE MET SOUS TENSION MAIS NE FONCTIONNE PAS CORRECTEMENT 1 Les batteries ne sont pas connect es Le syst me a besoin de batteries pour...

Reviews: