background image

6

Wear protective goggles when working overhead to protect your eyes from injury.

Disengage all existing garage door locks to avoid damage to the garage door.

To avoid serious personal injury from entanglement, remove all ropes connected to the garage door before

installing the opener.

INSTALLATION SECTION

Header Wall

2

Level

(optional)

1

3

Structural

Supports

OPTIONAL

CEILING

MOUNT

FOR

HEADER

BRACKET

Unfinished

Ceiling

4

2

The header bracket must be rigidly fastened to a

structural support of the garage. Reinforce the wall or

ceiling with a 40 mm (1-1/2") board if necessary. Failure

to comply may result in improper operation of safety

reverse system.

You can attach the header bracket either to the header wall

(1) or to the ceiling (3). Follow the instructions which will

work best for your particular requirements.
With the door closed, mark the vertical centre line (2) of the

garage door. Extend line onto header wall above the door.
Open door to highest point of travel. Draw an intersecting

horizontal line (4) on header wall at least 50 mm above high

point to provide travel clearance for top edge of door.

2

50 mm

3

1

4

A

150 mm
(6")

1 2

3

5

5

(50 to 200 mm depending on door type)

INSTALL THE HEADER BRACKET

HEADER BRACKET POSITIONING

1

2

Attach the Rail to the Header Bracket

• Position the assembled opener on the garage floor below the

header bracket. Use foam packing material as a protective

base.

NOTE: If the door spring is in the way youʼll need help.

Have someone hold the opener securely on a temporary

support to allow the rail to clear the spring.

• Position the rail bracket against the header bracket.

• Align the bracket holes and secure with the 80 mm clevis pin

and “R” clip (1) and (2).

ATTACH RAIL TO HEADER BRACKET

11

12

13

NOTE: Refer to vertical centre and horizontal lines created in

the previous section for proper placement of header bracket.

A

.

Wall mount:

centre the header bracket (1) on the vertical centre

line (2) with the bottom edge of the header bracket on the

horizontal line (4) (with the arrow pointing toward the ceiling).

Drill and secure the Header Bracket using the most suitable

variation of holes (5). If using the wood screws provided, use a

4.5 mm pilot drill. If securing to a metal fixture, self tapping “tek”

screws may be more suitable.

B

.

Ceiling mount:

extend vertical centre line (2) onto the ceiling.

Centre the header bracket (1) on the vertical mark no more than

150 mm (6") from the wall. Make sure the arrow is pointing

toward the opener. Drill and secure the Header Bracket using

the most suitable variation of holes (5). If using the wood screws

provided, use a 4.5 mm pilot drill. If securing to a metal fixture,

self tapping “tek” screws may be more suitable. For concrete

ceiling fixtures, 8 mm wall plugs are provided.

Summary of Contents for PowerLIft CS110MYQ

Page 1: ...ce CS110MYQ MyQ App Controlled Sectional Garage Door Opener Installation and Operating Instructions This manual contains IMPORTANT SAFETY information DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY chamberlaindiy com au chamberlaindiy co nz ...

Page 2: ... or wet space exposed to weather To avoid damage to very light doors such as fibreglass aluminium or steel doors an appropriate reinforcement should be added To do so contact the door manufacturer SAVE THESE INSTRUCTIONS Failure to comply with the following instructions may result in serious personal injury or property damage Read and follow all instructions carefully The garage door opener is des...

Page 3: ...e in close proximity to the powerhead This fitting is not part of the Opener hardware and must be supplied by the consumer 1 2 4 5 6 7 8 9 10 11 3 14 13 15 12 114A3361 For Service Call Installation Date 132A2900 RISK OF ENTRAPMENT Repeat Safety Reverse Test monthly Door must reverse on contact with a 40mm obstacle placed on the floor Make necessary adjustments AUTOMATIC DRIVE Keep away from the ar...

Page 4: ...n 80 mm 2 R clip 3 Hexagonal head screw 4 Nut M8 5 Flat washer M8 6 Clevis Pin 7 R clip 8 Screw ST6 x 50 mm 9 Screw ST6 3 x 18 mm 10 Wallplug 8mm Drill Bits 10 TOOLS REQUIRED 4 5 4 1 2 3 4 5 7 8 9 10 11 6 12 13 14 15 1 Header bracket 2 Belt 3 Rail 4 Trolley 5 Rail connecting piece 6 Rail bracket 7 Hanging bracket 8 Power cord 9 Opener 10 Manual release rope handle 11 Straight door arm 12 Curved do...

Page 5: ...larity Comment 0 E Serial port Green ve Serial Communication Input 1 Push button Red ve Dry Contact input for push button wired wall controls 2 Ground White ve Common terminal for push button 2 Ground White ve Common terminal for Safety Beams 3 Safety Sensor Gray ve Chamberlain Safety Beam Input pulsing type only 4 Door in door Green ve For Door in Door dry contact sensor see note below 5 Door in ...

Page 6: ...rews 5 This completes the assembly of the door opener to the rail FASTEN RAIL TO OPENER 9 10 The segmented rail is largely preassembled and consists of 4 parts The carriage push rod release handle the guide pulley and the lintel bracket with belt tensioner are in the front part A The seating for the drive shaft and the sprocket are in the rear part B Hardware items are placed in the rails during t...

Page 7: ...der Bracket Position the assembled opener on the garage floor below the header bracket Use foam packing material as a protective base NOTE If the door spring is in the way youʼll need help Have someone hold the opener securely on a temporary support to allow the rail to clear the spring Position the rail bracket against the header bracket Align the bracket holes and secure with the 80 mm clevis pi...

Page 8: ...between door and rail 1 Raise the opener onto support 2 Open the door completely place a 50 mm spacer between the door and the rail as shown 3 The final positioning of the rail should be relatively parallel to the horizontal door panels 14 Disengage the trolley mechanism see section Operating the manual release and slide it back towards the powerhead Secure the hanging push arm up into the rail as...

Page 9: ... a sound structural support above the opener 1 Postion the opener as in the previous step Check the rail is centred over the door Ensure the rail brackets fig 1 is on the Powerhead end of the rail in a position as close to the opener as possible X 2 If mounting directly onto the ceiling fig 2 screw the bracket directly into a structural support on the ceiling 3 If hanging the opener below the ceil...

Page 10: ...ly Remove the straight arm pivot and reassemble with the curved arm bracket ATTACH DOOR ARM TO TROLLEY OPERATING THE MANUAL RELEASE The manual release mechanism enables the door to be manually operated during power outages or in an emergency The RED Manual Release cord is preassembled to the trolley When the opener is installed the handle should be no higher then 1 8 metres from the floor The cord...

Page 11: ...ss and release the PROG Button The DOWN Arrow Button will begin to flash fig 4 5 Press and hold the DOWN Arrow Button until the door is in the desired DOWN position fig 5 NOTE The UP and DOWN Arrow Buttons can be used to move the door up and down as needed 6 Once the door is in the desired DOWN position press and release the PROG Button The UP Arrow Button and indicator LED will begin to flash fig...

Page 12: ...d position If it does repeat Program the Limits and Force then repeat safety reverse test 1 40mm The safety reverse system test is important Garage door must reverse on contact with a 40 mm obstacle laid flat on the floor Failure to properly adjust opener may result in serious personal injury from a closing garage door Repeat test once a month and adjust as needed 20 Low Standby Mode sub 1 watt is...

Page 13: ...d at a height of no greater than 100 mm off the garage floor The brackets are designed to be used for Wall or Floor fixing with a variety of hole combinations to achieve the desired results fig 1 Drill the required holes and install the brackets with wall plugs and screws provided Ensure they do not obstruct the door movement Align the Safety Beams to face each other and tighten if necessary The w...

Page 14: ...refer to the TROUBLESHOOTING section at the rear of the Opener Handbook Emergency Overide NOTE The door canʼt be closed using the MyQ app if an obstruction of Safety Beam failure has occurred However if needed the door can be closed by using the programmed button of a Keyless Entry Keypad E840C or the GREEN button located on the control panel Follow the process below With the door open Press the p...

Page 15: ...children to play near the door or with any door controls including remotes Smartphones Tablets or any internet device that has a Chamberlain MyQ app installed Power Pack It is important to use the AC DC PowerPack supplied with the product If the power pack is damaged or becomes unserviceable it must be replaced with an ANZ Compliant product of the same electrical performance INSTALLATION INSTRUCTI...

Page 16: ...o do from a computer or your internet enabled smartphone or tablet See step 3 for downloading the Chamberlain MyQ app and steps 5 and 6 for using the app To add the Chamberlain Internet Gateway to your account the GREEN LED on the Internet Gateway must be on continuously If the GREEN LED is not continuosly on see Step 1 Connect Create The Chamberlain Internet Gateway must have an internet connecti...

Page 17: ...onfigured separately These settings do not affect the web page login A four Digit PASSCODE can be created in place of your email and password credentials See Creating a Passcode below Default Chamberlain MyQ App Security Settings Launching App high security is initially set to ON You must enter your email and password credentials every time the app is launched Setting this to OFF allows the app to...

Page 18: ...e restarting the app will require the creation of a new passcode Apple iPhone iPad or iPod Touch Step 6 Android App Controls Controlling a device a garage door opener Go to Places Swipe right or left to select a device to see more than one door Tap the door image to open close door If a device is grayed out it is currently unavailable Security settings see step 4 for details Go to Account tab Tap ...

Page 19: ... continuously after power and network connections are completed NOTE The LED may blink intermittently with data traffic GREEN LED Off The router is not providing an IP address to the Chamberlain Internet Gateway Check your router settings and internet connections GREEN LED flashing steadily On Off The Chamberlain Internet Gateway has an IP address but is not accessing the Internet Check your route...

Page 20: ...hes twice 3 Press the UP button once for each 10 second increment required of TTC fig 2 eg twice for 20 seconds Press the DOWN arrow to reduce if needed 4 Press and release the PROG button to save this time fig 3 Courtesy light will flash once TTC is now activated TEST Operate the door to the UP position Keep clear of the Safety Beams and check the door closes after the preset time The down arrow ...

Page 21: ... The Courtesy light will flash twice indicating the deactivation has occurred NOTE Erasing all remote control codes as in the Wireless programming section will also delete this feature PARTIAL OPENING FEATURE PET Indicator LED Indicator LED Door Fully Closed fig 1 fig 2 fig 3 27 1 service www chamber a n de nfo chamber a n de B B A 2 114A3361 For Service Call Installation Date 3 132A2900 RISK OF E...

Page 22: ...nd Hold the yellow LEARN button on the opener until the indicator LED goes ON and continue holding for approx 6 seconds until the indicator LED goes out 2 Release the button all remote control and keyless entry codes are now erased Reprogram any accessory you wish to use To Erase all Remote Control Keyless Entry Device Codes MyQ enabled devices 1 Press and Hold the yellow LEARN button on the opene...

Page 23: ...e a Month Manually operate door If it is unbalanced or binding call a qualified door technician Check to be sure door opens closes fully Adjust limits and or force if necessary Repeat the safety reverse test Make any necessary adjustments Once a Year Lightly grease the belt and inside the rail assembly where the trolley slides Be careful to use gloves around any sharp metal edge of the rail Intern...

Page 24: ...installed during the manufacturing process and may have dislodged 12 The Up and DOWN arrows on the control panel are flashing in sequence Check the diagnostic code on next page 1 Opener doesn t operate from either door control or remote Does the opener have electric power Plug lamp into outlet If it doesn t light check the fuse box or the circuit breaker Some outlets are controlled by a wall switc...

Page 25: ...align both sensors to ensure both LEDs are steady and not flickering Make sure nothing is hanging or mounted on the door that would interrupt the sensors path while closing No RPM pulses have been detected Check the door manually for balance binding or obstructions Internally the possible cause may be the motor logic board or RPM sensor Try resetting door travel limits Contact service centre RPM p...

Page 26: ...ent Door Linkage Adjustable door arm Pull cord trolley release Safety Personal Push button stop in UP and DOWN direction Automatic safety reverse in both UP and DOWN direction Electronic Automatic force adjustment Electrical Transformer overload protector and low voltage push button wiring Limit Device Mechanical Passpoint RPM sensor Limit Adjustment Electronic Soft start Soft stop Electronic Dime...

Page 27: ...rol 3 Model 774AML Safety Beams 4 Model E1702C Quick release lock 5 Model E840C Wireless Keypad 35 Warranty Registration Register your warranty at chamberlaindiy com au warranty or chamberlaindiy co nz warranty 2016 The Chamberlain Group Inc TM Trademark of The Chamberlain Group Inc Registered Trademark of The Chamberlain Group Inc 26 ...

Page 28: ...r return the Unit to you This Chamberlain Limited Warranty does not cover any failure of or defect in the Unit due to 1 non compliance with the instructions regarding specifications installation operation maintenance and testing of the Unit or of any product with which the Unit is used 2 any attempt by a person other than a Professional Dealer to repair dismantle reinstall or move the Unit to anot...