Installation of photocells 

(Optional accessory)

Connecting the opener

Program opener and test

Setting the Limits

After installing and adjusting the door opener, photocells can be instal-

led� The instructions for installation are included in the scope of delivery 

of the light barrier and must be followed� 

The optional photocells 

ensure that the door is open, or remains open, if people, especially 

young children, are in the door area.

 By means of the photocells, a 

closing door is opened or an open door is obstructed from closing, if a 

person located in the door area interrupts the sensor beam� 

Photocells are particularly recommended for families with young 

children.

Connect opener in accordance with local rules and regulations to a

properly installed wall socket�

NOTE: When the opener is switched on, the operator light is also turned 

on for 2�5 minutes�

PROGRAMMING BUTTONS:

The programming buttons are located under a removable cover on the

back side of the garage door opener (see fig24).

1�  Press and hold the square Adjustment Button until the UP Button 

begins to flash.

 

2�  Press and hold the UP Button until the door is in the desired UP 

position� NOTE: The UP and DOWN Buttons can be used to move 

the door up and down as needed� 

3�  Once the door is in the desired UP position press and release the 

Adjustment Button. The garage door opener lights will flash and 

the DOWN Button will begin to flash.

 

4�  Press and hold the DOWN Button until the door is in the desired 

DOWN position� Make sure the rail does not bend� NOTE: The UP 

and DOWN Buttons can be used to move the door up and down as 

needed� 

5�  Once the door is in the desired DOWN position press and release 

the Adjustment Button. The garage door opener lights will flash 

and the UP Button will begin to flash.

 

6�  Press and release the UP Button� When the door travels to the pro 

grammed UP position, the DOWN Button will begin to flash. Note: 

IF the door does not travel to the UP position the travel limit pro-

gramming failed� Begin again with step1� If door travel is too short 

please refer to section 33 ”Frequently Asked Questions”� 

7�  Press and release the DOWN Button� The door will travel to the 

programmed DOWN position� Programming is complete�

Travel limits regulate the points at which the door will stop when moving 

up or down� Follow the steps below to set the limits�

This operator is equipped with a two speed system that is automatically 

set by the software� Canopy or 1-piece garage doors will automatically 

run in slow speed to insure a safe operation according regulatory� Doors 

traveling shorter than 190 cm will run automatically slow�

 

INTRODUCTION:

Your garage door opener is designed with electronic controls to make 

setup and adjustments easy� The adjustments allow you to program 

where the door will stop in the open (UP) and close (DOWN) position� 

The electronic controls sense the amount of force required to open and 

close the door� The force is adjusted automatically when you program 

the travel�

 

NOTE:

If anything interferes with the door’s upward travel it will stop� If anything 

interferes with the door’s downward travel, it will reverse� To watch a 

short instructional video on programming your new garage door opener 

use your smartphone to read the Code on this manuals back side

or visit www�chamberlain�eu�

The door opener should only be used if the operator can see 

the entire door area and is assured that it is free of obstac-

les and the door opener is set correctly� No one may pass 

through the door while it is moving. Before the first opening operation, 

check that all the facilities that are not needed are turned off. Remove 

all mounting aids and tools from the pivot area of the door�

Summary of Contents for MyQ LM75EVK

Page 1: ...no en Monterings og bruksanvisning for port pner Assembly and operating instructions for Garage Door Opener LM75EVK...

Page 2: ...ntering av portfeste 6 Feste portarmen p l pevognen 6 Elektrisk tilkobling 6 Montering av veggkonsollen eller Multifunksjons veggkonsol Valgfritt tilbeh r 6 Installasjon av fotocelle Valgfritt tilbeh...

Page 3: ...yller verneklasse 2 og beh ver ingen jording For unng skader p spesielt lette porter for eksempel glassfiber aluminium eller st lporter m en tilsvarende forsterkning installeres V r vennlig og ta kont...

Page 4: ...g m en ekstern n d pner bli installert A n dels port kun med horison al l peskinne B n dels port med vertikal og horisontal l peskinne krever spesi alportarm E The Chamberlain Arm og lysport The Prote...

Page 5: ...nt halvveis sammentrykket Fj ren m v re stram og ha mulighet til fj re under drift Ved arbeid over hodet m man bruke vernebriller for beskytte ynene For unng skader p porten m alle sperrer l ser deakt...

Page 6: ...ca 30 40 MERK Den b yde portarmen kan ogs bli frafalt n r portbeslaget er festet helt i vre portkant Install r veggkonsollen slik at man kan se garasjeporten men utenfor omr det rundt porten og ports...

Page 7: ...n firkantede programmeringstasten Motorbe lysningen blinker kort og OPP tasten begynner igjen blinke 6 Trykk p OPP tasten N r porten n r den innstilte grenseposisjo nen for OPP begynner NED tasten bli...

Page 8: ...rnstyring Programmering av mottakeren for ytterligere h ndsenderkoder ved hjelp av den gule runde innl ringstasten 1 Trykk og slipp den gule innl ringstasten p motoren Innl ringsindikatoren lyser i 30...

Page 9: ...ulig programmere MyQ kompatible apparater F lg instruksene online Henvisning Hvis minst ett apparat f eks garasjeportmotor er blitt programmert p internett grensesnittet Gateway lyser den bl LED en pe...

Page 10: ...yr optisk ved lysdioder og akustisk overv king av portens posisjon Porten kan lukkes via denne enheten krever fotoceller kan ikke pnes fra denne enheten O Str mtilf rsel til eksterne apparater tilkobl...

Page 11: ...j rer og festesteder m kontrolleres hyppig for tegn p slitasje skader eller mangelfull balanse M ikke benyttes n r man man m gjennomf re reparasjon seller justeringsarbeid da en mangel p anlegget elle...

Page 12: ...ere deg om mulighetene for deponering 1 Port pneren lar seg ikke sl p med radiostyring Er port pner koblet til str mforsyningen Sl r ikke en lampe som er koblet til st pselet seg p kontrolleres sikrin...

Page 13: ...den riktig Porten er meget tung eller i d rlig tilstand Kontakt en fagmann 14 Skinne til port pner b yer seg Porten er tung meget tung eller i d rlig tilstand Kontakt en fagmann Svinging i skinnen und...

Page 14: ...es 1 5 Porten beveger seg kun f cm stopper eller reverserer Port som g r tungt eller er defekt pne lukk porten for h nd og s rg for at funksjonen til porten rettes opp av en spesialist reparasjon 1 5...

Page 15: ...VAC 50 60 Hz Maks trekkraft 750 N Standby ved lukket port 0 8 W Motortype DC girmotor med permanentsm ring St yniv 54dB Fremdrift Tannrem Lengde p portens 2498 mm pningshastighet opp til 200 mm s Mak...

Page 16: ...tional accessory 7 Connecting the opener 7 Program opener and test 7 Setting the Limits 7 Test the Safety Reverse System 8 Program your opener and remote the Wireless push button optional 8 Connect th...

Page 17: ...njury due to entanglement remove all cables and chains connected to the door before installing the door opener During installation and electrical connection the local building and electrical regu lati...

Page 18: ...ight be required if the your garage ceiling has a cladding boards or similar 3 If your garage does not have a separate side entrance an external emergency release refer to section 34 Optional Accessor...

Page 19: ...2 80 m It may be necessary to place the drive temporarily higher so that the rail does not hit the springs in sectional doors The drive must either be well supported ladder or held firmly by a second...

Page 20: ...m the drive by pulling the red handle and manually pushing towards the door When the door is closed fix the curved door arm 9 on the door bracket with the bolt 17 and secure with cotter pin 18 Connect...

Page 21: ...and the UP Button will begin to flash 6 Press and release the UP Button When the door travels to the pro grammed UP position the DOWN Button will begin to flash Note IF the door does not travel to th...

Page 22: ...ds 1 2 Within 30 seconds press and hold the button on the hand held remote that you wish to operate your garage door 2 3 Release the button when the opener light blinks once It has learned the code No...

Page 23: ...ster eu or send us an e mail to info liftmaster eu D Instructions for Auto Close Feature Description of feature The Chamberlain Safety IR Sensors must be installed required by EN60335 2 95 Activate Pu...

Page 24: ...switched on at the factory After the lights go off and with the garage door closed Switch off under 1 watt standby 1 Disconnect device from the mains 2 Press the UP and DOWN buttons on the back on th...

Page 25: ...observe the following instructions for battery Batteries should not be treated as household waste All consumers are required by law to dispose of batteries properly at the designated collection point...

Page 26: ...e contact the service department Re program operating force Clear ice or snow in the closing area of the door If the door reverses upon reaching the door position Closed the limit switch must be set f...

Page 27: ...additional suspension on the rail can be a remedy 14 Rail bends on the opener Door is heavy very heavy stiff or in poor condition Call a specialist A swing of the rail while moving is a sign of an un...

Page 28: ...y open and close the door Check for binding or obstructions such as a broken spring or door lock correct as needed Check wiring connections at travel module and at the logic board Replace travel modul...

Page 29: ...220 240 VAC 50 60 Hz Max Pull Force 750 N Standby Power door fully closed 0 8 W Motor type DC gearmotor permanent lubrication Noise level 54dB Drive Mechanism Belt Length of Travel 2498 mm Opening sp...

Page 30: ...A B C D D X A B C D D 9 a b c d e g h i j k f l m 4 2 1 8 1 21 4x 8x 19 4x 8 1x 7 1x 13 1x 4 1x 5 4x 6 4x 2 3 4 5 6 9 8 11 12 7 20 10 3 7 6 10 1 ca 36 38 mm 8 13 mm 10 mm...

Page 31: ...11 1 3 10 20 4x 2 X 20 10 2x X 19 15 1 2 12 min 100mm max 150mm B A 2 6 21 19 13 13 14 14 X A B 11 21 6 0 50 cm 5 19 3 15 1 0 100 mm 2 100 130 mm 4x 7 B A 16 17 20 17 18 16 15...

Page 32: ...2 3 4 5 6 7 30 VDC LIGHT 1 2 0 2 0 1 2 2 3 7 4 5 6 white red white _ _ _ _ 771EV 772E G770E 771EVK white black 2 3 2 3 2 3 2 3 19 20 1 2 3 4 5 6 7 23 1 24 25 26 1 2 3 4 5 0 1 2 2 3 4 5 6 7 0 1 2 2 3 4...

Page 33: ...0 mm h j genstand der er blevet stillet p jorden it ATTENZIONE Pericolo di incastro Verificare sistematicamente e se necessario regolare in maniera adeguata onde assicurare che la porta torni indietro...

Page 34: ......

Page 35: ......

Page 36: ...Chamberlain GmbH Saar Lor Lux Str 19 66115 Saarbr cken Germany WEEE Reg Nr DE66256568 www liftmaster eu info liftmaster eu 2019 all rights reserved 114A4CLM75EVK 2...

Reviews: