The supervised edge system is capable of communicating in either of two channels, A or B. Each unit is set to the default communication 
channel A from the factory. Under most conditions the factory setting will not have to be changed. When two systems are used in close 
proximity (less than 6 feet), one system should be set to channel B.

To select Channel B the rear covers of both units must be removed and the jumpers marked in the following illustration must be placed 
over both pins. To select Channel A the jumper should be placed over one of the pins securing it for storage.

RECEIVER UNIT

TRANSMITTER UNIT

C H A N N E L   S E L E C T I O N

S P E C I F I C A T I O N S

Channel Selection

Jumper

Placed Ch. B
Removed Ch. A

Receiver

Transmitter Electric

              

Receiver JP1: Off Channel A

Transmitter JP2 Off Channel A 

On Channel B

On Channel B

 

Transmitter Pneumatic

PARAMETER

MINIMUM

MAXIMUM

TYPE

UNIT

OPERATING VOLTAGE

18
20

26.5
35

24
24

Vac
VDC

CURRENT

5

50

20

mA

RELAY CONTACTS

-

1.0
.5
.3

-

A for 30VDC
A for 125Vac
A for 60VDC

TEMPERATURE CHANGE

0

158

-

0F

HUMIDITY

10%

-

95%

Relative

SIZE

3.5 x 2.5 x 1.5

inches

PARAMETER

MINIMUM

MAXIMUM

TYPE

UNIT

OPERATING VOLTAGE

2.5

6

3

Vac

CURRENT

.1

20

10000

mA

SAFETY EDGE RESISTANCE

7.5K

15K

10K

Ohms

TEMPERATURE CHANGE

0

158

-

0F

HUMIDITY

10%

-

95%

Relative

SIZE

3.5 x 2.5 x 1.5

inches

6

Summary of Contents for LiftMaster 50-WSE-14

Page 1: ...iver Supervised fault occurs if normal supervisory conditions are not received Provides lock out on critical failure with electro mechanical operator and requires constant pressure to close with solid...

Page 2: ...or an AC connection The transmitter is connected to the safety edge and uses an internal 3V lithium battery for power Battery life is estimated at one year however conditions may vary For convenience...

Page 3: ...open position The receiver also may be mounted on the door s end bracket Optimal mounting position for the receiver will vary depending on the door PLACEMENT RECOMMENDATION Contact parts services for...

Page 4: ...rest transmitter 5 Slide 1 2 tubing into door astragal 6 Press 1 8 clear tubing onto barbed connector 7 Insert other end of barbed connector into hole of end plug from step 4 8 Cut 1 8 clear tubing to...

Page 5: ...run inside the sleeve around the cable Apply a thin layer of adhesive to the edge of the cable bushing to seal 1 Using scissors or a sharp razor to cut edge to length adding a total of 1 for end caps...

Page 6: ...ecuring it for storage RECEIVER UNIT TRANSMITTER UNIT C H A N N E L S E L E C T I O N S P E C I F I C AT I O N S Channel Selection Jumper Placed Ch B Removed Ch A Receiver Transmitter Electric Receive...

Page 7: ...afety edge is shorted or partially shorted Check the edge connections in transmitter and then measure the safety edge resistance Correct tolerance is 7 5k Ohms to 15k Ohms Replace edge if out of toler...

Page 8: ...2008 The Chamberlain Group Inc All Rights Reserved 01 18837D...

Reviews: