The supervised edge system is capable of communicating in either of two channels, A or B. Each unit is set to the default communication
channel A from the factory. Under most conditions the factory setting will not have to be changed. When two systems are used in close
proximity (less than 6 feet), one system should be set to channel B.
To select Channel B the rear covers of both units must be removed and the jumpers marked in the following illustration must be placed
over both pins. To select Channel A the jumper should be placed over one of the pins securing it for storage.
RECEIVER UNIT
TRANSMITTER UNIT
C H A N N E L S E L E C T I O N
S P E C I F I C A T I O N S
Channel Selection
Jumper
Placed Ch. B
Removed Ch. A
Receiver
Transmitter Electric
Receiver JP1: Off Channel A
Transmitter JP2 Off Channel A
On Channel B
On Channel B
Transmitter Pneumatic
PARAMETER
MINIMUM
MAXIMUM
TYPE
UNIT
OPERATING VOLTAGE
18
20
26.5
35
24
24
Vac
VDC
CURRENT
5
50
20
mA
RELAY CONTACTS
-
1.0
.5
.3
-
A for 30VDC
A for 125Vac
A for 60VDC
TEMPERATURE CHANGE
0
158
-
0F
HUMIDITY
10%
-
95%
Relative
SIZE
3.5 x 2.5 x 1.5
inches
PARAMETER
MINIMUM
MAXIMUM
TYPE
UNIT
OPERATING VOLTAGE
2.5
6
3
Vac
CURRENT
.1
20
10000
mA
SAFETY EDGE RESISTANCE
7.5K
15K
10K
Ohms
TEMPERATURE CHANGE
0
158
-
0F
HUMIDITY
10%
-
95%
Relative
SIZE
3.5 x 2.5 x 1.5
inches
6