Step

 

Current 

Setting 

Purpose 

Required 

Digits 

Acceptable Input 

23 

 

Alert 7, Service Cycle Alert 

Same as step 23 

23 

 

Alert 8, Fire Open Alert 

Same as step 23 

23 

 

Alert 9, Radio Input Stuck Alert 

Same as step 23 

24 

 

Alert Pager Phone Number 

Up to 16 

Maximum of 16 digits, 00 erases digits 

25 

 

Alert Pager Pause 

10 - 60, in seconds 

26 

 

Alert Pager Extension Number 

Up to 16 

Maximum of 16 digits, 00 erases digits 

27 

 

Alert Pager Extension Pause 

Up to 2 

0 - 60, in seconds 

28 

 

Alert Unit ID Number 

Up to 16 

Maximum of 16 digits, 00 erases digits 

29 

 

Alert Call Terminator 

0 - 2, 0 = None, 1 = #, 2 = 

 

(asterisk) 

30 

 

Alert Test 

1 - 9, refers to step 23 Alerts 1-9 

31 

 

Alert Attempts 

Up to 3 

0 - 100 (0 = no attempt) 

32 

 

Service Call Feature 

Up to 5 

0 to 65000, (0 disables Service Call) 

33 

 

Service Call Cycle Counter  

Must enter 

00 

00 (clears Service Call Cycle Counter) 

34 

 

Holiday Schedule 

nMMDD, n = Holiday number - 0 - 9 
0 = first holiday, 9 = tenth holiday 
MM = Two digits for month  
DD = Two digits for date  

35 

 

Schedule Enable 

0 -1, (0 = Disable, 1 = Enable) 

36 

 

Gate Schedule 
 
NOTE: 
HHMM = opening time 
hhmm = closing time 

11 digits 

dsHHMMhhmmo,  
d = One digit - week day. 
(1 = Sun., 7 = Sat., 8 = Holiday) 
s = One digit for segment(s), (1 or 2) 
HH = Two digits for hour. (24 hr. format) 
MM = Two digits for minutes  
hh = Two digits for hour. (24 hr. format) 
mm = Two digits for minutes 
o = Holiday option (0 - 2 
0 = Ignore if date falls on holiday 
1 = Use if date falls on holiday 
2 = Use day 8 if date falls on holiday 

39 

 

Reset Unit 

Must enter 

101010 

101010, (resets unit) 

40 

 

Alert Modem Phone Number 

Up to 16 

Maximum of 16 digits, 00 erases digits 

41 

 

Alert Call Schedule 
 
NOTE: 
HHMM = start call time 
hhmm = end call time 

11 digits 

dsHHMMhhmmo,  
d = One digit – week day. 
(1 = Sun., 7 = Sat., 8 = Holiday) 
s = One digit for segment(s), (1 or 2) 
HH = Two digits for hour. (24 hr. format) 
MM = Two digits for minutes  
hh = Two digits for hour. (24 hr. format) 
mm = Two digits for minutes 
o = Holiday option (0 – 2 
0 = Ignore if date falls on holiday 
1 = Use if date falls on holiday 
2 = Use day 8 if date falls on holiday 

 

 

LIMITED WARRANTY 

LiftMaster warranties the X1 board’s CPU against original manufacturing defects for a period of one (1) year, measured from the 
day of initial shipment by LiftMaster.

  

This warranty is conditioned upon LiftMaster being paid in full for all equipment; this warranty 

is not effective until such payment in full has been received.  The warranty period shown above applies only to the X1 board’s 
CPU.  Since this is a manufacturer's warranty, not a dealer's warranty, installation, removal, and freight charges are not part of this 
warranty, nor shall the installer be held liable in any way for removal, repair or installation of the components unless otherwise 
stated in a separate dealer's warranty.  This warranty does not extend to systems or compartments that show evidence of damage 
caused by vandalism, acts of God (e.g., lightning, flood), abuse, or unauthorized or improper service. 
 

 
 
 

Summary of Contents for Estate Series X1 LiftMaster Professional

Page 1: ... If the board s 7 segment LED spells out HELLO letter by letter you have correctly inserted the chip If it spells out NO FID you have a bad chip Return the bad chip to LiftMaster and insert a new chip If the board s 7 segment LED does not emit a light you may have incorrectly inserted the chip Cycle power a few times to be sure and then go to step 4 under Removing the Existing Chip and follow the ...

Page 2: ...rrupt Bar Backup If Closing Up to 3 0 499 in inches 14 Interrupt Bar Backup If Opening Up to 3 0 499 in inches 15 Return Factory Set Defaults 6 101010 Partial default reset all except steps 24 26 28 34 and 36 191919 Full default reset 17 Change Password 6 Any combination of 6 digits 18 Verify Password 6 User designated password 19 Set Date And Time 11 with 2 more optional for seconds YYMMDDdhhmm s...

Page 3: ... 0 Ignore if date falls on holiday 1 Use if date falls on holiday 2 Use day 8 if date falls on holiday 39 Reset Unit Must enter 101010 101010 resets unit 40 Alert Modem Phone Number Up to 16 Maximum of 16 digits 00 erases digits 41 Alert Call Schedule NOTE HHMM start call time hhmm end call time 11 digits dsHHMMhhmmo d One digit week day 1 Sun 7 Sat 8 Holiday s One digit for segment s 1 or 2 HH Tw...

Page 4: ...uch information may not be distributed without the prior written consent of LiftMaster The software and firmware included in the LiftMaster product as they relate to this documentation are also protected by copyright and contain information proprietary to LiftMaster FOR TECHNICAL SUPPORT OR TO ORDER REPLACEMENT PARTS CALL OUR TOLL FREE NUMBER 800 528 2806 Tucson AZ Monday thru Friday 5 AM 6 PM Sat...

Reviews: