Doc 01-18540
Page 2 of 4
PROGRAMMING REFERENCE TABLE
To ENTER programming mode:
Enter
000000.
To VIEW an operator’s current setting:
A) Enter step number, B) Press # (pound sign).
To PROGRAM a command:
A) Enter step number, B) Enter desired data, C) Press # (pound sign).
To EXIT programming mode:
Enter 00 #.
Step
Current
Setting
Purpose
Required
Digits
Acceptable Input
01
Gate Type
1
0 - 2 (0 = Slide, 1 = Swing, 2 = Barrier)
02
Operator Type
1
0 - 2 (0 = Single, 1 = Master,
2 = Slave)
03
Gate Pair Type
1
0 - 3 (0 = Bipart, 1 = Bipart Latch,
2 = Trap, 3 = Tandem
04
Warn When
1
0 - 3
0 = moving, 1 = closing,
2 = not closed, 3 = alarm per step 23
05
Warn Time Before Moving
Up to 2
0 - 30, in seconds
06
Anti-Tailgate Enable
1
0 - 1 (0 = Disabled, 1 = Enabled)
07
Latch Delay Time
Up to 3
1 - 250 in 0.4 second increments
08
Reclose Time
Up to 3
0 - 250, in seconds
09
Maximum Retry Count
1
0 - 2 (0 = Do not retry)
10
Retry Pause Time
Up to 2
30 - 99, in seconds
11
Reverse Sense Backup Closing
Up to 3
0 - 499, in inches
12
Reverse Sense Backup Opening
Up to 3
0 - 499, in inches
13
Interrupt Bar Backup If Closing
Up to 3
0 - 499, in inches
14
Interrupt Bar Backup If Opening
Up to 3
0 - 499, in inches
15
Return Factory Set Defaults
6
101010 = Partial default reset (all except
steps 24, 26, 28, 34 and 36)
191919 = Full default reset
17
Change Password
6
Any combination of 6 digits
18
Verify Password
6
User designated password
19
Set Date And Time
11, with 2
more
optional
(for
seconds)
YYMMDDdhhmm[ss]
YY = Last two digits of year
MM = Two digits for month
DD = Two digits for date
d = One digit for week day. (1 = Sun.)
hh = Two digits for hour. (24 hr. format)
mm = Two digits for minutes
ss = Two digits for seconds (optional)
20
Rings Before Answer
Up to 2
1 - 19
21
Answer Ring Override Time
Up to 2
0 - 30, in seconds
22
Alert Calling
1
0 - 3,
0 = None
1 = Pager
2 = Modem
3 = Scheduled (per step 41)
23
Alert 1, Drivetrain Failure Alert
1
0 - 3
0 = None
1 = Call telephone receiver
2 = Trigger warning device,
3 = Call phone & trigger warning device
23
Alert 2, Interrupt Bar Fault Alert
1
Same as step 23
23
Alert 3, Overcurrent Fault Alert
1
Same as step 23,
23
Alert 4, Motor Protector Switch
Open Alert
1
Same as step 23
23
Alert 5, Loop Failure Alert
1
Same as step 23
23
Alert 6, Master/Slave
Communication Failure Alert
1
Same as step 23