HAVING A PROBLEM?
Motor does not run
• Public electricity supply failure: Check with a
neighbor.
• Circuit breaker has tripped or fuse is blown: Check
house overload protector. If necessary, have an
authorized electrician redistribute the load.
• The switch is defective: Have it checked by an
authorized electrician and replaced if necessary.
• Repeated operation may have tripped the motor
overload protector switch: Wait 15 minutes and try
again.
Motor runs intermittently
• Have the wiring connection between switch and
motor checked by an authorized electrician. Replace
if necessary.
Motor does not shut off
• Check to be sure tube adapter is positioned all the
way up to the stop on the shaft.
• Check to be sure the motor has been inserted all the
way into the shaft.
GB
11
N
L1.2 (brown)
M
CD
L1.1 (black)
N (blue)
Main
230 V/50 Hz
PE (yellow-green)
2I
1I
PI
E
Control Cable
4 x 0,75
1 yellow-green
2 blue
3 black
4 brown
Equipment Grounding Conductor PE
Color Scale for Drive Table
Nuetral MP
Phase Direction of Rotation 1
Phase Direction of Rotation 2
M
CD
11
Connection of the
Model 703280 switch
L1.2 (brown)
L1.1 (black)
N (blue)
Main
230 V/50 Hz
PE (yellow-green)
Control Cable
4 x 0,75
1 yellow-green
2 blue
3 black
4 brown
Equipment Grounding Conductor PE
Color Scale for Drive Table
Nuetral MP
Phase Direction of Rotation 1
Phase Direction of Rotation 2
M
CD
12
Connection of the
Model 703285 switch
M
CD
L
13
8
9
5
4
10
7
14:00
Rollotimer
1
2
3
6
11
ACCESSORIES
No
Item
Description
(14.1) 704636
CD10
120785ASA
CD20E4
120758ASA
CD30E4
120756ASA
CD50E4
(14.2) TAO70ASA
Tube adapter, octagonal 70mm
(Not for CD10)
400431
Tube adapter, octagonal 40 mm
(Not for CD10)
(14.3) TAP65ASA
Tube adapter, profile shaft 65 mm
(Not for CD10)
(14.4) 120053
Octagonal tube 60mm (Not for CD10)
(list length when ordering)
(14.5) 120995
End Cap for 120053
(14.6) WTMZ1
One central control module for each
connected motor
(14.7) WTMT2
Timer
(14.8) 703280
Wallswitch
(14.9) WTMLS1
Solar sensor for WTMT2
(14.10) 121084
Universal wall bearing for 120053
(14.11) TCS1ED
Wall Switch
041A801417
Programmable Timer
708218
Accessory pack CD10 - Motor bracket
708223
Accessory pack CD10 - Adapter
041TM707008 Accessory pack CD20E4, CD30E4, CD50E4
Declaration of Conformity
Tubular Motor....................................................................................Model No. CD10, CD20E4
........................................................................................................................CD30E4, CD50E4
is in conformity to the applicable sections of Standards .....................EN55014, EN610003,
................................................................................ETS RES 0908, EN60555, & EN60335-1
per the provisions & all amendments of EU Directives .....................73/23/EEC, 89/336EEC
IDeclaration of Incorporation
Tubular Motor Model CD10, CD20E4, CD30E4 and Model CD50E4, when installed and
maintained according to all the Manufacturer’s instructions in combination with a shutter
which has also been installed and maintained according to all the Manufacturer’s
instructions, meets the provisions of EU Directive 89/392EEC and all amendments.
I, the undersigned, hereby declare that the equipment specified above and any
accessory listed in the manual conforms to the above Directives and Standards.
Colin B. Willmott
Chief Engineer
Chamberlain GmbH
D-66793 Saarwellingen
Juli, 1998
14