Disconnect power BEFORE making electrical connections.
Below is an example of a wiring setup for gate access. Gate access can be
wired to Door 1 or 2.
NOTE:
Power Supplies shall be UL Listed Commercial 294 or 603 power limited output Power Supplies.
LAN
ADMIN
DR
Y
RL
Y1
WE
T
PSE1
Po
E
DR
Y
WE
T
RL
Y2
HR
TB
T
READER 1
IO 1
REX
CO
M
DOOR
RED GRN 12V BUZ GND D1 D0
IO 2
REX
CO
M
DOOR
READER 2
RED GRN 12V BUZ GND D1 D0
NC
COM
NO
NC
COM
NO
NC
COM
NO
NC
COM
NO
-12IN+
+
-
RFID ANTENNA
KEYPAD
REQUEST TO EXIT
PRIMARY RELAY
AUXILIARY RELAY
WIEGAND
READER
PUSH
BUTTON
GATE OPERATOR
EXTERNAL FREE EXIT
LOOP DETECTOR
OR
OR
OR
NOTES:
• The length of the unshielded
wires should be kept to a minimum
to avoid electrical noise.
• When extending the reader connection,
the shield wire must be connected to an
earth ground bus, but should NEVER be
connected at the reader.
NOTE:
Power supply for
RFID antenna is not provided.
DO NOT use the power supply
for the door controller.
NOTE:
For KPR2000 keypad
wire the pink and black (ground)
wires together.
RED LED - brown
GREEN LED - orange
DA
TA 1 - white
DA
TA 0 - green
GROUND - black
12Vdc - red
COM
REX
OPEN
COM
COM
NO
NC
Common
(Exit Input)
Model MG1300
NORMALLY CLOSE
Use 18-22 AWG
COMMON
Power for Maglock
(Not Provided)
DO
NOT
use the power
supply for the
controller
For AC Power:
Install a Siemens S10K30MOV
(Metal Oxide Varistor) (provided) or equivalent
For DC Power:
Install a 1N4005 diode
or equivalent