IMPORTANT NOTES:
1. The 3-Button Control Station provided must be connected for operation.
2. If a STOP button is not used, a jumper must be placed between terminals 3 and 5.
3. If INTERLOCK is not used a jumper must be placed between terminals 3 and 4.
4. When adding accessories, install them one at a time and test each one after it is added to ensure proper installation and operation
with the Commercial Door Operator.
3 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND STOP BUTTON
2 OR MORE
KEY LOCKOUT
7
6
3
5
Stop
Close
Open
Stop
Close
Open
7
6
3
5
Stop
Close
Open
2 BUTTON STATION OR 3 POSITION KEYSWITCH WITH SPRING RETURN TO CENTER
STANDARD
7
6
3
Close
Open
C2
MODE ONLY
2 OR MORE
7
6
3
Close
Open
Close
Open
C2
MODE ONLY
DEVICE TO REVERSE
EXTERNAL INTERLOCK
1
2
3
4
3
4
Remove Factory Installed Jumper
When Interlock is Used
ONE
2 OR MORE
STANDARD
7
6
3
5
Stop
Close
Open
All Wiring Types
Keyswitch
Sensing Device
Note:
For photo-eyes connection options see
OPTIONAL SAFETY DEVICE CONFIGURATION section.
See note 2.
See note 2.
C O N T R O L C O N N E C T I O N D I A G R A M
01-34210B
© 2008, The Chamberlain Group, Inc.
All Rights Reserved