en-7
TECHNICAL DATA OF MOTOR CONTROL:
Voltage
230VAC
Transformer
230/24VAC minimum60VA
Output motor
24VDC max.
Supply accessories
24VDC - 100mA
Operating temperature
-20°C - +55°C
Degree of protection
IP54
30VDC
MOTOR
MASTER
+
-
MOTOR
SECOND
24V/150mA BRN GRN WHT YEL
MASTER
BRN GRN WHT YEL
SECOND
COM PHOTO
1 2
COM STOP/*
8.2
Ω
DIAGNOSTIC
LEARN
PHO1
PHO2
STOP/8.2K
JP2
JP1
OPEN / PED
1/2 MOTOR
STOP/8.2K
P1
P2
P3
L
N
250V/2A
250V/2A
TRANSFORMER
230VAC
INPUT
24VAC
RADIO
801719
/ LAMP
Ω
8.2
+
+ -
RED
RED
BLUE
BLUE
230VAC
+
+
+
Ω
+
PE
PE
WIRING OF CONTROL / SUMMARY
a) start with still dead 230Volts supply cable on the left side of the box.
b) Attach cable eye to ground wire. Then connect ground wire to base
plate with washer and nut (exactly as shown in picture detail).
Connect all other cables to control.
Attention:
Check repeatedly that cable colours are connected correctly
to motor. Otherwise motor might be damaged or will not operate
properly. Pay special attention when using distribution boxes.
We recommend the following accessories:
LA400-JB40E Kit for
cable extension of one installation unit. Consists of 12m of
cable 6-pole with identical colours, distribution box IP65,cable screw
joints and fastening material