Erase/Reset 

• 

To erase users: 

NOTE: 

Erasing a user will erase 

ALL 

stored fingerprints. User 

does 

NOT 

need to reprogram to opener. 

1. Open cover and wait until Ready 

LED is lit. 

2. Enrolled user must 

slowly 

and 

firmly

swipe fingerprint.

3. Press and hold the Enroll button for at

least 6 seconds. The Pass LED and Fail
LED will flash for 15 seconds. During 
this time the Resend button is active.
After 15 seconds the Enroll and Ready
LEDs will light indicating fingerprints are
erased. The unit will return to Enroll
mode.

ENROLL 

FAIL 

RETRY 

SEND 

PAS S 

READY 

ENROLL 

• 

To return unit to Factory Reset state: 

NOTE: 

Factory reset state will erase 

ALL 

stored fingerprints. 

This method should be used 

ONLY 

when an enrolled user is 

not available as it requires user to reprogram unit to opener. 

1. Open cover and wait until Ready 

LED is lit. 

2. Press and hold the Enroll button 

until all LEDs turn off. Release 
button. 

3. Again press and hold the Enroll 

button until the Ready and Enroll 
LEDs are lit and not flashing. 

ENROLL 

FAI L 

RETRY 

SEND 

PA SS 

READY 

ENROLL 

Troubleshooting 

• 

If no known enrolled users are available: 

— The memory must be erased using the Factory Reset

process.

• 

If the unit does not recognize a swiped fingerprint: 

— Ensure that the Ready LED is lit before you swipe. 

— Ensure that fingerprint is swiped correctly (See Tips for 

Success). 

— Ensure that fingerprint is enrolled. 

— Ensure that sufficient pressure is being applied to sensor 

strip (do not press too hard). 

— Ensure that the sensor and finger are not wet. 

• 

If the unit is in Enroll mode at power up: 

— Complete enrollment process for initial user. 

— The initial enroll process failed (signaled by a lit Enroll LED 

and Fail LED) and must be repeated. 

• 

If enrolling new user and all LEDs flash and unit returns 
to Ready mode: 

— The memory is full. In order to add new user, the memory 

needs to be erased. Refer to Erase User or Factory Reset. 

• 

If the unit does not wake: 

— A button may be stuck. Press Enroll and Resend buttons 

to ensure free movement. 

— The batteries may need to be replaced. 

• 

If the Fail LED flashes during use: 

— The batteries need to be replaced. 

NOTE: 

If sensor is dirty, user should wipe sensor with a clean 

finger. It is recommended that the sensor be periodically 
cleaned with a lint-free cloth dampened with alcohol. 

The Battery 

To prevent possible SERIOUS INJURY or DEATH: 

• NEVER allow small children near batteries. 
• If battery is swallowed, immediately notify doctor. 

The batteries should produce power for 
at least one year. Replace when the 
Fail LED flashes during use. The unit 
requires 4 AAA batteries. 

Dispose of old batteries properly. 

1. Slide cover completely off. 

2. Unscrew the two screws and 

remove the battery cover. 

3. Replace the batteries. Screw the 

battery cover back on. 

4. Slide cover back into place. 

ENROLL 

FAIL 

RETRY 

SEND 

PASS 

READY 

ENROLL 

Scre

w

Co

v

er 

Battery 
Co

v

er 

Replacement parts: 

Cover  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .41A6481 

NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of 
this receiver and/or transmitter are prohibited, except for changing the code setting or replacing 
the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. 
Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the 
following two conditions: (1) this device may not cause harmful interference, and (2) this device 
must accept any interference received, including interference that may cause undesired operation. 

FOR SERVICE DIAL OUR TOLL FREE NUMBER: 

1-800-528-9131 

© 2007, The Chamberlain Group, Inc. 

114A3460 

All Rights Reserved 

Summary of Contents for 942FPC

Page 1: ...se a 120Vac polarized outlet for the receiver which is OUT OF THE REACH OF CHILDREN Plug receiver into selected outlet Return power to the opener Actuator Cover Power Indicator Light Terminals Bell Wire Channels SMART Indicator Light Connect Bell Wire To Garage Door Opener Terminals SMART Actuator Bell Wire To prevent possible SERIOUS INJURY or DEATH from electrocution Be sure power is not connect...

Page 2: ...ial User NOTE The unit requires 3 passed swipes to enroll a user 1 Open cover to turn unit on Wait until Enroll LED and Ready LED are lit not 1 flashing ENROLL SEND ENROLL PASS FAIL READY RETRY 2 Swipe finger slowly and firmly down the 2 sensor strip until three passed swipes are made NOTE The Pass LED will light for a passed swipe The Retry LED will light if another swipe is needed Swipe slowly a...

Page 3: ...ton at 1 second intervals for up to 5 seconds until the door moves Programming is complete NOTE If unit will not program to opener repeat the steps above or refer to Troubleshooting 2 ENROLL SEND ENROLL PASS FAIL READY RETRY 3 4 ENROLL SEND ENROLL PASS FAIL READY RETRY 5 Step 6 Operation 1 Open cover and wait until Ready LED 1 is lit ENROLL SEND ENROLL PASS FAIL READY RETRY 2 Swipe finger slowly a...

Page 4: ...Enroll LED and Fail LED and must be repeated If enrolling new user and all LEDs flash and unit returns to Ready mode The memory is full In order to add new user the memory needs to be erased Refer to Erase User or Factory Reset If the unit does not wake A button may be stuck Press Enroll and Resend buttons to ensure free movement The batteries may need to be replaced If the Fail LED flashes during...

Page 5: ...longueur du fil de sonnerie dépendra de l endroit où on installera le récepteur Réinstaller le couvercle de l actuateur 6 Choisir une prise de courant polarisée de 120 Vcc pour le récepteur et qui est HORS DE LA PORTÉE DES ENFANTS Brancher le récepteur dans la prise choisie Rétablir le courant de l ouvre porte de garage Couvercle Témoin d alimentation d actuateur Bornes Circuits du Témoin fil de s...

Page 6: ...sages réussis 1 Ouvrez le couvercle pour allumer l appareil Patientez jusqu à ce que les LED Enroll 1 Inscrire et Ready Prêt s allument elles ne doivent pas clignoter ENROLL SEND ENROLL PASS FAIL READY RETRY 2 Faites glisser votre doigt lentement et fermement sur le capteur de bande jusqu à ce que trois passages réussis soient réalisés 2 REMARQUE La LED Pass Réussi s allume lorsqu un passage est r...

Page 7: ...ez le bouton 5 Resend Renvoyer à 1 seconde d intervalle pendant 5 secondes jusqu à ce que les lumières du dispositif d ouverture clignotent ou que la porte bouge La programmation est terminée REMARQUE Si l appareil ne se programme pas au dispositif d ouverture répétez les étapes ci dessus ou reportez vous à la section Dépannage Étape 6 Fonctionnement 1 Ouvrez le couvercle et patientez jusqu à ce q...

Page 8: ...lisateur initial La procédure d inscription initiale a échoué signalé par les LED Enroll Inscrire et Fail Échec qui s allument et doit être répétée Si à l inscription d un nouvel utilisateur toutes les LED clignotent et l appareil revient en mode Ready Prêt La mémoire est pleine Pour ajouter un nouvel utilisateur la mémoire doit être effacée Reportez vous à l étape Suppression d utilisateur ou Res...

Reviews: