Step 12:
Install a
Rough Service
lamp bulb (75 Watt maximum) firmly
in the light socket. Light bulbs in door openers are subject to vibration
during normal operation which may shorten their life spans. Rough Service
bulbs, available at most hardware stores, are recommended. Fit Light
Diffuser tabs into the panel tabs as shown.
STEP 11: Connecting The Electrical Power
Consult the label on the rear panel of the Opener to
determine its proper working voltage. Normally it will be marked for 115V, 60 cycle operation. (If it is an export
model designed for 220V, 50 cycle operation, the label will clearly indicate this.) The Opener must be plugged
into a properly grounded receptacle within 3 FT of the Power Unit.
A GFI Type receptacle is recommended.
Do not use 2-prong adapters and do not use extension cords for anything more than temporary hook-up and testing
purposes. Receptacle wiring should be No. 14 or heavier, and
must be in compliance with local building and
electrical codes.
If local codes require permanent wiring, a GFI type circuit breaker is recommended to protect the line. Remove
the Strain Relief Bushing and withdraw the Line Cord from the rear of the Power Unit to expose the three
insulated connectors. Cut the wire at the rubber jacket of the Line Cord and wire in permanently, employing
proper wiring practices. Discard Strain Relief. It is not used with permanent wiring.
Using the two wires (black & white) that were left the
line cord was cut, splice in the permanent connections
.
Permanent Wiring Connection
Normal
Connection
Ground Wire
110053-1
110055-1
Closed Limit
Stop Location
Open Limit
Stop Location
Fully Open
Fully Closed
Trolley
Door Arm
Connection
Door Arm
Door Arm
Bracket
Open
Door
Closed Door
Door Arm
IMPROPER WIRING COULD CAUSE
ELECTROCUTION OR DAMAGE TO
CIRCUITRY. FOLLOW LOCAL
BUILDING AND ELECTRICAL CODES.
WARNING
C: INSTALLING THE OPERATOR
Slide door arm and trolley toward door; connect
the tube assembly to the door bracket with the
3/8” diameter bolt and locking nut, tightening
enough to allow for door arm pivot. Do not
overtighten the locking nut.
Press door control button and run opener through
full open and close cycles, adjusting the limit
stops as required to fully open and close the door.
At full closed position, the door arm assembly
should compress approximately one inch.
HOW TO OPERATE THE DOOR MANUALLY -
MANUAL RELEASE DISCONNECT
The door should be fully closed, if possible, before
using the manual disconnect. Weak or broken
springs could allow an open door to fall rapidly.
Property damage or serious personal injury could
result. Do not use the manual release handle to pull
the door open or closed.
Your opener is equipped with a manual release recessed
trolley-type disconnect system, enabling manual
operation of the garage door during a power failure.
The trolley is disconnected from the chain by pulling
down on the red release handle, allowing the garage
door to be operated manually.
The trolley will
automatically
reconnect when
power is
restored and the
door is
activated.
If the manual release is used, close the door before
reactivating the opener.
NOTE: Outside keylock manual releases are an
available accessory and are recommended for
garages without a service entrance.
Manual
Release
Knob
Trolley
Clips