Model 15000-3S & 15000-SPRINTER
Installation, Operation and Maintenance
Page
10
Rev. 8/13/19
15-3S-IOM-A.doc
A
RM
I
NSTALLATION
36) Lubricate the arm pin or carriage arm pin hole
with “anti-seize” and install the arms. Insure that
the arm restraint gears engage and disengage
properly. Arm restraints should disengage when
lift is fully lowered (
Fig 18
).
37) Extend the footpad to both extents and apply
“anti-seize” to the retaining ring.
Fig. 18-Arm Installation
38) Make sure all the arm screws are tight using a
Philips Head Screw Driver. Slide all the arms out
so they are fully extended making sure that the
intermediate is retained in the female and the
male is retained in the intermediate arm.
39) Locate the two pre-drilled holes on the back of
each column 19” up from the top of the base
plate. Center the adapter rack and attach with
5/16”-18NC x 1” Lg hex flange cap screw and
5/16” hex flange nut (
Fig. 19
)
.
Fig. 19-Adapter Rack Installation
E
LECTRICAL
See Figure 20 for the following steps.
40) Wire tie Limit Switch cord to column hydraulic
line and power unit line.
41) Connect the Overhead Limit Switch Cord to
Power Unit as shown in
Fig. 20
.
42) Connect Power Unit to suitable electrical source
as shown in
Fig. 20
.
43)
IMPORTANT
:
A
FTER WIRING HAS BEEN
COMPLETED
,
TEST OPERATION OF
P
OWER
U
NIT
&
O
VERHEAD
L
IMIT SWITCH
.
W
HILE RAISING LIFT
,
OPERATE
O
VERHEAD
S
HUTOFF
B
AR
.
P
OWER
U
NIT
M
OTOR SHOULD STOP WHEN
S
HUTOFF
B
AR IS
RAISED
.