Model 15000-3S & 15000-SPRINTER
Installation, Operation and Maintenance
Page
3
Rev. 8/13/19
15-3S-IOM-A.doc
WARNING
V
ERTICAL
C
LEARANCE
Check the height of the area where the lift is to be
installed. Clearance should be calculated based on
the full raised height of the lift.
Failure by purchaser to
provide adequate clearance
could result in unsatisfactory
lift performance, property damage, or personal
injury.
F
LOORING
Be certain you have the proper concrete floor to
properly handle the loaded lift. Floor should be in
generally good condition with no large cracks,
spalling or deterioration.
Minimum requirements for concrete are 4 inches
minimum depth, with steel reinforcement, 3500
psi, cured for 28 days per local commercial
practice
. Floor should be level within 3/8 inch over
the installation area. No anchors should be installed
within 8 inches of any crack, edge, or expansion
joint. If these conditions cannot be met, a pad may
be poured to accommodate the lift.
Check with local building inspectors and/or permits
office for any special instructions or approvals
required for your installation.
A qualified person should be consulted to address
seismic loads and other local or state requirements.
Failure by purchaser to
provide the recommended
mounting surface could result
in unsatisfactory lift performance, property
damage, or personal injury.
L
OCATION
This lift has been evaluated for indoor use only with
an operating ambient temp. range of 5 – 40°C (41
–
104°F)
E
LECTRICAL
R
EQUIREMENTS
For lift installation and operation it is necessary to
have a dedicated circuit with circuit breaker or time
delay fuse. Refer to wiring diagram for circuit sizing.
A
IR
R
EQUIREMENTS
This lift is equipped with an air operated lock release
system.
The air supplied to the lift must be clean,
dry, lubricated, and regulated to 90-120 psi, FRL
(
F
ilter/
R
egulator/
L
ubricator). The FRL must be
within 30 feet of lift.
Failure to provide clean, dry,
lubricated, and pressure regulated air will void
warranty on pneumatic components
.
S
AFETY
N
OTICES AND
D
ECALS
For your safety, and the safety of others, read and
understand all of the safety notices and decals
included here.
R
EAD ENTIRE MANUAL BEFORE ASSEMBLING
,
INSTALLING
,
OPERATING
,
OR SERVICING THIS
EQUIPMENT
.
P
ROPER MAINTENANCE AND INSPECTION IS NECESSARY
FOR SAFE OPERATION
.
DO
NOT
OPERATE A DAMAGED LIFT
.
Safety decals similar to those shown here are found
on a properly installed lift. Be sure that all safety
decals have been correctly installed on the Power
Unit reservoir. Verify that all authorized operators
know the location of these decals and fully
understand their meaning. Replace worn, faded, or
damaged decals promptly.
Do not attempt to raise a
vehicle on the lift until the lift
has been correctly installed
and adjusted as described in this manual.
WARNING
WARNING