Page. 63 of 63
7.2 SEALED-CHAMBER
Model Name
25 FF
30 FF
35 FF
DRAFT
CE certification (pin)
General
comments
Boiler type
C12-C32-C42-C52-C62-B22-B32
Max./min. nominal heat input central heating
(Hi)
kW
25,8/11 30/13 34,4/14
Max./min. nominal heat input central heating
(Hs)
kW
28,6/12,2 33,3/14,4
Max./min. nominal heat input D.H.W. mode
(Hi)
kW
27/11 31,3/13 36/14
Max./min. nominal heat input D.H.W. mode
(Hs)
kW
30/12,2 34,7/14,4
Max./min. Central Heating power
24/9,5
28/11,6
13,2/32,3
Combustion efficiency (at flue)
% 95,4/85,9
94,8/85,4 94,7
Efficiency of nominal heat output (60/80 °C)
HI/Hs
% 94,3/84,9
93,6/84,3 93,6
Efficiency at 30 % 47°C
Hi/Hs
% 93,2/83,9
93,7/84,4 91,1
Efficiency at minimum
Hi/Hs
% 90,4/81,4 ---
89
Number of efficiency stars (Directive 92/42/EEC)
no.
Max. heat loss to the casing (
∆
T = 50°C)
% 1,1 1,6 1,2
Heat loss through flue gas exhaust when burner operating
% 4,6 5,2 5,3
Energy perfo
rma
nce
Heat loss through flue gas exhaust when burner switched off
% 0,2 0,2 0,4
Residual discharge head
mbar
1,0 0,75
NOx class
3 3 3
Flue gas temperature (G20)
°C
108,8 100 108
CO
2
content (G20)
% 7,14 6,89 7
CO content (0%O
2
)
ppm
97 76,6 95
O
2
content (G20)
% 7,68 8,51 8
Max. flue gas output (G20)
kg/h
57,68 60,3 74
Emissions
Excess air
% 57,62
60,99 61
Load losses water side (max) (
∆
T = 20 °C)
mbar
200 200
200
Residual head for the system
bar
0,25 0,2 0,25
Expansion vessel pre-charge pressure
bar
1 1 1
Minimum load pressure for the system
bar
0,4 0,4 0,4
Maximum central heating circuit pressure
bar
3 3 3
Expansion vessel capacity
litres
8 8 8
Central heating
cir
cuit
Max./min. heating temperature
°C
80/40 80/40
80/40
Max./min. Domestic Hot Water temperature
°C
60 / 36
60 / 36
60 /36
Specific output of D.H.W. system (10 min. with
∆
T=30°C)
litres/min
12,1 14 16
D.H.W. flow rate
∆
T=25°C
litres/min
14,5 16,3 19,2
D.H.W. flow rate
∆
T=35°C
litres/min
10,4 12 13,7
Comfort performance stars (EN13203)
D.H.W. minimum flow rate
litres/min
1,6 1,6 1,6
D.H.W. circuit
Max./min. domestic hot water pressure
bar
6 6 6
Power supply voltage/frequency
V/Hz
230/50
Total power consumption
W
126 138 151
Minimum operating temperature
°C
5 5 5
Electrical
and
environment
data
Electrical system grade of protection
IP
X4D
X4D
X4D
Weight
kg
31 31 33
Weight and
dimensions
Dimensions (W x H x D) with tap handing kit
mm
440x793x420
Summary of Contents for TALIA
Page 1: ...Product Guide Release 01_16 05 07 TALIA ...