Page. 48 of 63
4.2.4 Hydraulic
circuit
LEGEND
1
Expansion
vessel
7
3-bar safety valve
2
Primary heat exchanger
8
Hot water flow meter
3
Safety thermostat (overheating) 105°C
9
Modulating circulation pump with deaerator
4
Primary exchanger flow sensor
10
3-way diverter valve motor
5
Secondary exchanger
11
Primary exchanger inlet sensor
6
Boiler drain valve