Page. 43 of 63
4.1 DIAGNOSTIC
The new display fitted in this boiler range is very useful for describe boiler faults.
Different indications indicate which type of error it is and what you have to do (reset, no reset …….)
A little text describe perfectly the type of error and it is a real benefit for the after sale service to save time.
There are two types of errors for malfunctions:
- Shutdown (solved by resetting);
- Safety stop (No Reset: the boiler will start working again properly when the cause is removed).
There is a third type of error code that is used to indicate a malfunction that does not stop the boiler which continues to
work properly (Indication).
The Shutdown and the Safety stop are alternatively displayed with the respective error code and the writing "Err."
4.1.1 Error
codes
The error codes are divided in seven different functional units, in other words the first figure indicates which functional
unit of the boiler is involved in the error:
1 XX
Primary
circui
2 XX
DHW
circuit
3 XX
Electronic
PCB
4 XX
Communication
with
peripherals
5 XX
Ignition and detection
6 XX
Air inlet / Exhaust flue outlet
7 XX
Zones
NOTE
For more details please, see the Training Manual.
4.1.2
Complete information on boiler status
A Menu totally dedicated to the maintenance
service gives, together with the info button a
complete series of information concerning the
boiler status.
The Menu 8 in particular is useful to set the
periodical maintenance intervention warning
and the name and the telephone number of
the Technical service always available for the
end user when he access to the Info button.
A menu totally dedicated to the maintenance
service give.
Error code
Boiler in Shutdown or in
Safety stop
Boiler in lookout
(push Reset
button)
Error description
MENU 8
Boiler status
Boiler Temperature
Solar & Storage
Service
Statistics
Error History
Service Contact
Service
Months\rto Next Maintenance
Mainten On Days Act
Maint Warn Reset
Service Contact
Service Name
Service Phone Nr
Error History
Last 10 Errors with date
Reset Error List
Example : Menu 850
Month for next maintenance
Next time in 10 month
(example)