45
Technische eigenschappen
ARIANE
X
T
PL
US
THERMODYNAMIC PERFORMANCE OF EXTERNAL UNIT IN HEATING/COOLING MODE
The water heat exchanger fouling factor is 0 (m
2
K)/W for all conditions.
*
Standard Eurovent LCP/A/CHF conditions in heating mode: water heat exchanger entering/leaving water temperature 30 °C/35 °C, outside air temperature 7 °C db/6 °C wb.
Standard Eurovent LCP/A/CHF conditions in cooling mode: water heat exchanger entering/leaving water temperature 23 °C/18 °C, outside air temperature 35 °C.
** Standard Eurovent LCP/A/AC conditions in heating mode: water heat exchanger entering/leaving water temperature 40 °C/45 °C, outside air temperature 7 °C db/6 °C wb.
Standard Eurovent LCP/A/AC conditions in cooling mode: water heat exchanger entering/leaving water temperature 12 °C/7 °C, outside air temperature 35 °C.
*** Conditions in heating mode: entering/leaving water temperature 55 °C/a, outside air temperature 7 °C db/6 °C wb. Performances are in accordance with EN 14511.
**** Based on the following conditions: entering/leaving water temperature 35 °C/30 °C, outside air temperature 7 °C.
† Based on the following conditions: entering/leaving water temperature 12 °C/7 °C, outside air temperature 35 °C.
Note: The sound pressure level is measured in a hemisperic fi eld at 4 m distance from the unit.
MODEL
12 kW
15 kW
12 T kW
15 T kW
Data at Eurovent LCP /A/CHF conditions*
Nominal heating capacity
kW
11,9
14,5
12
15
Power input
kW
3,01
3,54
2,79
3.57
COP kW/kW
3,95
4,09
4,30
4.20
Eurovent class, heating
B
A
A
A
Nominal cooling capacity
kW
10.24
13.04
10.20
13
Power input
kW
1.17
1.90
1.96
EER
kW/kW
2.96
2.95
3
2.91
Eurovent class, cooling
B
B
B
B
Data at Eurovent LCP /A/AC conditions**
Nominal heating capacity
kW
12,9
14
11,2
14,5
Power input
kW
4,26
4,32
3,34
4,39
COP
kW/kW
3,03
3,23
3,35
3,30
Eurovent class, heating
A
B
A
A
A
Nominal cooling capacity
kW
10,2
13
10,2
13
Power input
kW
3,46
4,42
3,40
4,47
EER kW/kW
2,96
2,95
3
2,91
ESEER part-load performance
kW/kW
4,2
4,3
4,4
4,3
Eurovent class, cooling
B
B
B
B
Nominal heating capacity, radiator applications***
kW
10,27
11,66
11,05
12
Power input
kW
4,60
4,13
3,96
4,21
COP kW/kW
2,79
2,82
2,90
2,85
Net water volume
R-410A
Maximum water-side operating pressure
DC twin-rotary
Water pressure drop, X version (CHF)
PMV
Water connections, inlet/outlet (MPT gas)
Netto watervolume
l
0.8
0.8
0.8
0,8
Maximum waterzijdige bedrijfsdruk
kPa
300
300
300
300
Drukverlies water, X versie (CHF)
kPa
26
33
26
33
Wateraansluitingen, ingang/uitgang (MPT gas)
in
1
Ventilators Propellerventilators
Aantal/diameter
mm
2/495
2/495
2/495
2/495
Aantal schroeven
3