background image

3

INSTALLATION INSTRUCTIONS

FOR QUALIFIED GAS INSTALLER

A masonry shelf may be fitted 800mm above the fireplace

 but under no  

 circumstances  should  any  electrical  equipment  such  as  a  TV  be  positioned                                                                                    
above.  Any ornaments positioned above the fireplace must be able to 
withstand the elevated temperatures and moisture. No combustible 
materials whatsoever must be used or placed  
 above the fireplace.   

Unpacking 
 

Carefully undo the strapping to separate loose parts and remove all plastic  

 

protective sheeting.

Positioning and Sizing   
   

Confirm that the size of Fireplace chosen is the right size for the room. build  

 

up a masonry platform to the customers design, with a suitable hole to drop  

 

the fireplace into, so that it rests on the surrounding rim. 

Provide a vent for the primary air to the burner by means of 2x brick-size   
holes, leading into the cavity below the unit. 

Connect up according to SANS 10087-1  
 

Connect a copper pipe from the gas supply via a regulator, complying with  

 

SANS 1237, to the Ø8 compression fitting on the control valve, taking into 

 

account the distance from the gas supply, to calculate the size of the copper  

 pipe.

Setting up 

1.  Insert the burner with the venturi facing the gas jet, and ensure the burner is 

seated correctly.

2.  Fill the burner with the special glass pebbles. 

Use only the number of 

pebbles supplied.

Testing and Commissioning 
 

Turn on the gas supply and test for leaks with soapy water. 

 

Ensure that the 

WORKING PRESSURE is 2,1 kPa at the control valve

 

See checklist. 

 

Briefing the customer 

 

All instructions must be handed over to the user for safekeeping. Instruct the 

 

customer how to turn the gas on and off and how to light and control the fire.

 

After commissioning the unit the customer should be instructed on the safe  

 

use of it and the need for regular servicing. Frequency of service depends on  

 

usage, but must be carried out at the first sign of malfunction and at least  

 

once in 2 years.

 

Summary of Contents for VFSL800-N

Page 1: ...ating Instruction Manual Please read these instructions carefully before installation use and retain them for future reference Natural Gas VFSL800 N These appliances conform to the requirements of SAN...

Page 2: ...S T Y LE SAF E T Y Q U A LITY THAT L A S T S CONGRATULATIONS o n y o u r p u r c h a s e o f a CHAD O CHEF Fireplace a n d W E L C O M E t o t h e CHAD O CHEF family...

Page 3: ...ATION REQUIREMENTS 2 INSTALLATION INSTRUCTIONS 3 FOR QUALIFIED GAS INSTALLER 3 NG6801 VALVE Operating Instructions 4 NG6801 VALVE Pressure Testing 4 Checklist For Gas Installer 5 Caution 5 Warnings 6...

Page 4: ...s the installer s responsibility to do these calculations on behalf of the home owner 6 This appliance may only be installed by a registered Natural Gas installer and must comply with the installation...

Page 5: ...in bedrooms or bathrooms where the humidity levels are too high See page 1 Avoid areas where there are strong draughts which may be generated by outside doors It is recommend that the fireplace should...

Page 6: ...nit Connect up according to SANS 10087 1 Connect a copper pipe from the gas supply via a regulator complying with SANS 1237 to the 8 compression fitting on the control valve taking into account the di...

Page 7: ...s before repeating the ignition procedure 5 Continue turning the knob anticlockwise to the HIGH position and the main burner should light after a few seconds 6 Select the required HIGH or LOW setting...

Page 8: ...re glass pebbles than recommended and supplied See Page 2 The room must be bigger than the minimum room size for that fireplace See Page 2 Ensure that there is adequate ventilation in the box housing...

Page 9: ...WARNING CARBON MONOXIDE POISONING CAN LEAD TO DEATH Carbon monoxide poisoning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs the...

Page 10: ...of malfunction and at least once in 2 years Spiders are the biggest pests because they tend to occupy the smallest of holes which will be in the burner venturi or the pilot air holes If spiders are a...

Page 11: ...r This does not mean that it is rust proof it will require regular maintenance to preserve this protective surface layer in order to enjoy the high quality standard that is to be expected from Chad O...

Page 12: ...Manufactured By Chad o Engineering PO Box 986 Honeydew 2040 Tel 011 668 1910 Email Sales chad o chef co za www chad o chef co za...

Reviews: