The Guarantee given by Chad-O-Engineering (Pty) Ltd covers the working 

components, on all Chad-O-Chef Gas Fireplaces for the period of 2 Years 

(+ 1 Year t’s & c’s apply), covering manufacturing defects caused in the 

manufacturing process. This does not cover component malfunction if the 

product is not installed by a registered Gas Installer, or the product is 

modified after leaving the factory. 

Chad-O-Engineering (Pty) Ltd will not be held responsible in the event of 

rust.  Stainless Steel is inherently corrosion resistant when compared to 

other metals, due to its thin protective surface layer.  This does not mean 

that it is rust-proof & it will require regular maintenance to preserve this 

protective surface layer in order to enjoy the high-quality standard that is 

to be expected from Chad-O-Chef. 

Read your complete Instruction manual & ensure that you understand it 

fully.  If you have any concerns, please contact our service department for 

clarity. 

Product Name:  ______________________________________________ 
Serial No:   

______________________________________________ 

Describe the fault:   ____________________________________________ 
____________________________________________________________ 
____________________________________________________________ 
Contact Details:  ______________________________________________ 
 

Please attach a copy of the Gas Installation certificate & invoice and email 

to: 

[email protected]

 

Summary of Contents for VFSL800-N

Page 1: ...ating Instruction Manual Please read these instructions carefully before installation use and retain them for future reference Natural Gas VFSL800 N These appliances conform to the requirements of SAN...

Page 2: ...S T Y LE SAF E T Y Q U A LITY THAT L A S T S CONGRATULATIONS o n y o u r p u r c h a s e o f a CHAD O CHEF Fireplace a n d W E L C O M E t o t h e CHAD O CHEF family...

Page 3: ...ATION REQUIREMENTS 2 INSTALLATION INSTRUCTIONS 3 FOR QUALIFIED GAS INSTALLER 3 NG6801 VALVE Operating Instructions 4 NG6801 VALVE Pressure Testing 4 Checklist For Gas Installer 5 Caution 5 Warnings 6...

Page 4: ...s the installer s responsibility to do these calculations on behalf of the home owner 6 This appliance may only be installed by a registered Natural Gas installer and must comply with the installation...

Page 5: ...in bedrooms or bathrooms where the humidity levels are too high See page 1 Avoid areas where there are strong draughts which may be generated by outside doors It is recommend that the fireplace should...

Page 6: ...nit Connect up according to SANS 10087 1 Connect a copper pipe from the gas supply via a regulator complying with SANS 1237 to the 8 compression fitting on the control valve taking into account the di...

Page 7: ...s before repeating the ignition procedure 5 Continue turning the knob anticlockwise to the HIGH position and the main burner should light after a few seconds 6 Select the required HIGH or LOW setting...

Page 8: ...re glass pebbles than recommended and supplied See Page 2 The room must be bigger than the minimum room size for that fireplace See Page 2 Ensure that there is adequate ventilation in the box housing...

Page 9: ...WARNING CARBON MONOXIDE POISONING CAN LEAD TO DEATH Carbon monoxide poisoning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs the...

Page 10: ...of malfunction and at least once in 2 years Spiders are the biggest pests because they tend to occupy the smallest of holes which will be in the burner venturi or the pilot air holes If spiders are a...

Page 11: ...r This does not mean that it is rust proof it will require regular maintenance to preserve this protective surface layer in order to enjoy the high quality standard that is to be expected from Chad O...

Page 12: ...Manufactured By Chad o Engineering PO Box 986 Honeydew 2040 Tel 011 668 1910 Email Sales chad o chef co za www chad o chef co za...