2
SPECIFICATIONS
INSTALLATION REQUIREMENTS
Model VFSL800-N
Gas type
NG
Operating pressure
2,1 kPa
Min Regulator size to comply with SANS 1237
N/A
Max. gas consumption
N/A
Max. mJ input
N/A
Max. kW input
5.8 kW/h
Gas inlet connection
Ø8mm compression
Ignition
Piezo Spark
Oxygen depletion system ( Pilot )
ODS min 18.5% O2
Min Room size without permanent ventilation
57m³
Your VFSL800-N Fireplace is designed to
drop into a hole prepared
in a masonry construction.
In order to function correctly the unit needs adequate ventilation holes
to be cut into the masonry construction housing the unit
(2x brick-sized holes). - see diagram on pg.6
Choosing a site:
This fireplace may be installed in any room in a home except in bedrooms or
bathrooms where the humidity levels are too high. (See page 1)
Avoid areas where there are strong draughts, which may be generated by
outside doors. It is recommend that the fireplace
should not
be installed
within 500mm of any air vent, as this could affect the working of the ODS.
This fireplace is to be installed in an island setting, as it is not suitable to
be installed against a wall.
Clearances to combustible materials:
Combustible materials are defined as wood, fabrics, or other materials likely
to burn when exposed to flame. Any other material which is likely to discolour,
melt, or lose shape when exposed to moderate heat, should fall into the
same category.
Min clearance to the sides
100 mm
Min clearance to the sides for curtains & fabric
500 mm
Min clearance to the ceiling
800 mm
Min clearance to a floor ( including carpet )
100 mm
Min clearance to combustible furniture in front
1000mm