background image

Fig 2

Safety loop

700mm
min.

Spa blower

Blower located below the
spa water level using a
safety loop to avoid flooding
the blower

40mm PVC
pressure pipe

Fig 1

Blower located 700mm above
the spa water level to avoid
flooding the blower

700mm
minimum

Spa blower

Use 40mm PVC
pressure pipe

Fig 4

To pool

Spa blower

Double safety loop using an automatic vent valve for portable spas

40mm PVC
pressure pipe

(A)

3mm vent hole

Water relief valve automatically
closes when blower in use

Fig 3

Check
valve

To pool

Spa blower

Double safety loop with check valve for under cabinet portable
spa installations

40mm PVC
pressure pipe

(A)

3mm vent hole

Addendum to the CE Installation

Instructions for Australia & New Zealand 

IMPORTANT:

The Air Blower model designation:

MES-900-240/50  -  MES-700-240/50  -  MESB-900-240/50

MESF-900-240/50  -  MESF-700-240/50  -  MESF-B900-240/50

ME-B900-240/50-AMP 10”  -  MESF-B900-240/50-AMP 10” -  MES-B900-240/50-AMP 10”

All comply with the requirements of AS/NZS3350.2.60 

1)

The Millenium blower has passed all electrical and environmental

regulations -EMC. AS3136/NZS6232 and relevant provisions of 

AS/NZS3100.

2)

The Millenium blower must be installed in an enclosure rated at IPX5

(AUS8NZ)

In all cases refer to your national wiring rules or codes of electrical prac-

tice.  In order to prevent a hazard, if the supply cable is damaged or the

unit is not working it must be returned to the manufacturer or an authorised

service agent for repair.  This is a Class 1 appliance and must be connect-

ed to the permanent wiring.  The appliance should be supplied through a

residual current device (RCD) with a rated tripping current not exceeding

30mA.  This appliance must have a switch or other means of all pole

disconnection from the supply, having a contact separation of at least 3

mm, and must be incorporated in the fixed wiring to the appliance.

Refer to AS/NZ5 3000 : 2000 and IEC 60364 Part7 (Europe) for guidance with

compliance to the wiring codes for wet area and equipotential bonding.

IN GROUND SPA INSTALLATION

1.

The blower must be in a dry area as close as practical to the spa.  In 

installations more than 4 meters from the pool, the safety loop should 

be close to the spa. 

2. 

Safety loops and risers - to avoid water damage to the blower, the 

blower should be installed at least 700mm above the water level in 

the spa (fig. 1) or be protected by a safety loop (Fig 2).  Water dam

age is not covered by warranty.

3. 

All piping should be in 40mm PVC pressure pipe.

4. 

The minimum ventilation (free space around the blower) should be 

50sq.cm in accordance with AS/NZS2023:1995.

PORTABLE SPA INSTALLATION

1. 

Portable spas require a double safety loop plus a check valve (as in 

Fig 3) or a vent valve (as in fig 4). 

2. 

A 3mm hole a point (A) is recommended to allow accumulated

condensation to drain out.

3. 

All piping should be in 40mm PVC pressure pipe.

4.

After wet testing the spa, the blower should be disconnected for the

safety loop to stop residual water getting into the blower during transit. 

2006-09-05

www.cgair.com

Summary of Contents for MILLENIUM M0-230/50

Page 1: ...Canada Hergestell und gedruckt in Kanada For b blower m models P Pour lles m mod les d de s souffleurs P Para m modelos d de s sopladores F F r G Gebl se M Model MILLENIUM ME 230 50 ME LL 230 50 M0 23...

Page 2: ...set the blower duration at five minutes maximum Regulate the water temperature to a moderately warm level These levels can be later increased for additional massaging effects Your physiological respon...

Page 3: ...BOX GREEN GROUND BROWN LINE BLUE NEUTRAL GREEN BROWN BLUE ELECTRICAL FEEDER 230V BLOWER AN INDEPENDENT ELECTRONIC CONTROL AIR SWITCH OR WALL TIMER MUST BE INSTALLED TO OPERATE THE BLOWER 230V 10A 240...

Page 4: ...rera un doux massage complet L effet du massage est produit par l injection d air chaud travers les jets dans la baignoire L utilisation du syst me de massage pendant une longue p riode de temps avec...

Page 5: ...mentionn es ci dessus la p riode de garantie relative tout produit install pour fins de d monstration d bute au moment o le produit est mis en d monstration En aucun cas CG AIR SYST MES INC ne peut t...

Page 6: ...a muy caliente puede producir mareo o cansancio Para las primeras utilizaciones recomendamos no m s de cinco minutos cada vez y el agua no muy caliente M s tarde se puede aumentar la temperatura del a...

Page 7: ...ado o la provincia donde se encuentre CG AIR SYSTEMES INC se reserva el derecho de discontinuar o de modificar los modelos colores y especificaciones sin infringir ninguna obligaci n INSTALACI N EL CT...

Page 8: ...ssociation UL Underwriters Laboratory sowie beim T V Bauart registriert Der Ursprung des therapeutischen Luftmassagesystems Das Luftmassagesystem auch bekannt unter dem Namen Balneotherapie ist die Ve...

Page 9: ...ch ein Produkt des selben Wertes Kommerzielle Beschr nkungen Eingeschlossen in die vorherig stipulierten Bedingungen und Beschr nkungen sind Produkte welche f r Demonstrationszwecke angeschlossen und...

Page 10: ...er or an authorised service agent for repair This is a Class 1 appliance and must be connect ed to the permanent wiring The appliance should be supplied through a residual current device RCD with a ra...

Reviews: