CET s.r.l. Parallel Message Display
page 10
2.4.1. Command TYPE 3: Address in BCD code
Inputs
SY
D
C
B
A
Command TYPE 3
IMP
0
0
1
1
This code informs the display unit that the first 8 inputs represent the position address (0 to 80) in BCD code
where the next variable will be laid.
D8
D7
D6
D5
D4
D3
D2
D1
D0
2
8
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
3
rd
2
nd
1
st
3
rd
DIGIT
2
nd
DIGIT
1
st
DIGIT
Number in the range 0 to 199
2.4.2. Command TYPE 4: Address in BINARY code
Inputs
SY
D
C
B
A
Command TYPE 4
IMP
0
1
0
0
This code informs the display unit that the first 8 inputs represent the position address (0 to 80) in BINARY code
where the next variable will be laid.
D8
D7
D6
D5
D4
D3
D2
D1
D0
-
-
2
6
2
5
2
4
2
3
2
2
2
1
2
0
Number in BINARY code in the range 0 to 80
Coding and number are always read at the variation 0 1 of the synchronism signal SY.
2.4.3. Command TYPE 2: Variable in BCD code
Inputs
SY
D
C
B
A
Command TYPE 2
IMP
0
0
1
0