48
12. Configuring UPS for EBM Numbers
To ensure the LCD displays the correct battery capacity, configure the UPS
for the correct number of EBMs:
1.
Enter settings mode: Press and hold the left button for longer than 1
second.
This will cause the UPS to go into settings mode.
2.
Select settings items: Press the left and right buttons to cycle
through the settings until you reach the settings item “EBM”.
3.
Enter settings item: Press the Enter button
for longer than one
second to enter the setting item.
4.
Select setting value: Use the left and right buttons to select the
number of EBMs according to your UPS configuration. (up to a maximum
of 9)
5.
Confirm settings: Press and hold the Enter button
for one second,
and the UPS will then return to settings mode.
6.
Exit Settings mode: Press and hold the Enter button
for 1 second
or the Power button
for 0.5 second to exit settings mode.
*if required the service code is 4314