22.11. Reverting to Factory Defaults
It is possible to clear and default the system completely, resetting all programmed
settings to default values and clearing all learned remotes as well as gate limits.
To perform a complete reset:
Remove power from the unit by disconnecting both the mains supply and one battery
terminal
Press and hold the pushbutton
Reapply power to the unit (it makes no difference whether the battery or mains is
reconnected first)
Release the pushbutton
The controller is now defaulted
22.12. Factory Defaults schedule
Sensitivity
Autoclose status
Autoclose timer
Modes of Operation
PIRAC
PCM status
Speed
Light profile
Hi/Lo
On/Off
s
S, O, R
On/Off
On/Off
Hi/Lo
CUR, PFA, PFC
Lo
5s
Lo
Hi
Off
Off
S
Off
Off
Hi
CUR
Hi
45s
Hi
Unit
Minimum
Default
Maximum
Parameter
description
page 76
TABLE 4.